Quick Start Manual

160 Rockwell Automation Publication IASIMP-QS019E-EN-P - August 2013
Chapter 6 System Commissioning
PowerFlex 700 Drive Status Indicators
PowerFlex 70 EC Drive Status Indicators
Start-up Routines
Start-up routines are available for the PowerFlex 7-class drives through
Assisted Start-Up on the HIM module or the Start-Up Wizard from one of the software tools. The start-up
routines do not apply for a PowerFlex 755 drive used in CIP Motion applications.
The drive-mounted HIM module provides an assisted start-up and will step through configuration and
tuning.
A software-based start-up wizard is available in DriveExplorer™ software, DriveTools™, or with the Custom
Download AOP for the PowerFlex 7-class drives. The start-up wizard steps through configuration and
tuning.
For more information on drive start-up routines for PowerFlex 7-class drives, refer to the appropriate user manual
listed in Additional Resources on page 15.
Status Indicator Status
Pwr Solid green
STS Flashing green
Port Flashing green (depending on communication module)
Status Indicator Status
STS Flashing green
Port Flashing green (depending on communication module)
PWR
STS
PORT
MOD
NET A
NET B
PowerFlex 700
Status Indicators
STS
PORT
MOD
NET A
NET B
PowerFlex 70EC
Status Indicators