Install Your ArmorBlock Cable Base
To install the cable base:
Mount the cable base
Attach the module to the base
Attach the cables
These procedures are explained in detail in the following sections.
Mount the Cable Base
The cable base can be mounted either vertically or horizontally, using
3 screws. Cable bases accommodate 4 or 8 point ArmorBlock MaXum
modules. You must allow additional space for installation of 8 point
ArmorBlock MaXum module, which are longer than 4 point modules.
43332
When
installing a
cable base
with an 8
connector
module,
allow for
the
additional
length.
1792D-CB23
1.34in
34mm
1.63in
41.5mm
6.10in
155mm
4 connector
module
8.23in
209mm
8 connector
module
1.90in
48.18mm
2.70in
68.5mm
1.42in
36mm
0.64in
16.25mm
0.26in
6.5mm
4.21in
107mm
2.27in
57.6mm
6.10in
155mm
1.35in
34.25mm