Installation Instructions ArmorBlock MaXum 2 Input with Alarm/ 2 Output Module Series B (Cat. No. 1792D-2BVA2D) 41453 This ArmorBlock MaXum™ I/O module (Cat. No. 1792D-2BVA2D) is a stand-alone 24V dc I/O product which communicates via a DeviceNet™ network. The sealed housing of this module requires no enclosure. This model has 2 inputs with alarm and 2 outputs. Inputs are 24V dc automatically configured for PNP (sourcing) or NPN (sinking) devices. Outputs are also configured for sourcing.
ArmorBlock MaXum 2 Input with Alarm/ 2 Output Module Series B Package Contents Your package contains: • 1 ArmorBlock MaXum Module • Installation Instructions (Please note: Cable bases are ordered and shipped separately.) European Union Directive Compliance If this product has the CE mark it is approved for installation within the European Union and EEA regions. It has been designed and tested to meet the following directives.
ArmorBlock MaXum 2 Input with Alarm/ 2 Output Module Series B 3 Install Your ArmorBlock MaXum I/O Module To install the module: • • • • Set the node address Mount the module to the cable base Connect the cord sets Communicate with the module Each of these steps is explained in more detail in the following procedures. Set the Node Address Valid node addresses are 00 to 63. Set the node address using the rotary switches, RSNetWorx for DeviceNet™, DeviceNetManager™, or other software configuration tool.
ArmorBlock MaXum 2 Input with Alarm/ 2 Output Module Series B Refer to the illustration of the node address below. Example: Node address is set at 62, see small black dots. 30703-M The module is equipped with AutoBaud detect. AutoBaud lets the module read the settings already in use on your DeviceNet network and automatically adjusts to follow those settings.
ArmorBlock MaXum 2 Input with Alarm/ 2 Output Module Series B 5 To install the module:. IMPORTANT Proper alignment of the screws is necessary to complete the connections between the module contacts and the cable contacts. 1. Position the module over the mounted cable base. Align the three captive screws in the module with the accepting receptacles in the base. 2. Tighten the screws with a torque of 8 inch-pounds to secure the module to the base.
ArmorBlock MaXum 2 Input with Alarm/ 2 Output Module Series B Connect the Cord Sets to the MaXum Module This module uses 5 pin micro (12mm) style PCB mounted connectors. Four micro caps cover the connectors on your module. Remove the caps and connect your cord sets to the appropriate ports. Use the micro caps to cover and seal unused ports. A pinout diagram for the connectors is shown next.
ArmorBlock MaXum 2 Input with Alarm/ 2 Output Module Series B ATTENTION ! 7 • Make sure all connectors and caps are securely tightened to properly seal the connections against leaks and maintain IP67 requirements. • For maximum noise immunity, input and output cable return wires must be properly terminated. When inputs and outputs are connected in loopback, return wires should be connected together. • I/O cable length should be less than 30 meters. I/O connectors for this module are shown below.
ArmorBlock MaXum 2 Input with Alarm/ 2 Output Module Series B Communicate With Your ArmorBlock MaXum Module This ArmorBlock module’s I/O is exchanged with the master through a polled, change-of-state, or cyclic connection. The module consumes and produces I/O data as shown: Type of I/O Connections Consumes Cyclic 1 Byte Produces 2 Bytes Polled 1 Byte 2 Bytes Change-of-State 1 Byte 2 Bytes Cyclic - allows configuration of the block as an I/O client.
ArmorBlock MaXum 2 Input with Alarm/ 2 Output Module Series B 9 The word/bit definitions are explained below. Byte Bit Description Produces 0 00-01 Input status bits: When the bit is set (1), the input is on. Bit 00 = input 0, bit 01= input 1. Alarm Status bit: Bit 02=Alarm A0, bit 03=Alarm A1. Input Short Circuit Fault (ISC): ISC-A indicates a short circuit for input 0. Input Short Circuit Fault (ISC): ISC-B indicates a short circuit for input 1.
ArmorBlock MaXum 2 Input with Alarm/ 2 Output Module Series B Point indicators for this module are shown below.
ArmorBlock MaXum 2 Input with Alarm/ 2 Output Module Series B 11 The following table describes logic status indicators. Logic Status Indicators State Status Off Logic is disabled Solid Green Logic is enabled Flashing Green Local forces are applied and local logic is enabled The following table describes auxiliary power indicators. Auxiliary Power Indication Status None No Auxiliary Power Solid Green Auxiliary Power Present The following table describes I/O status indicators.
ArmorBlock MaXum 2 Input with Alarm/ 2 Output Module Series B Specifications 2 Input with Alarm / 2 Output Module - Cat. No. 1792D-2BVA2D Input Specification Max. Inputs per block 2 - 3 wire or dry contact PNP or NPN devices or 2 - 4 wire PNP or NPN devices Sensor Source Current (per input) 100mA - Off-Wire Sense Current 0.5mA - On-state Voltage 25V dc 10V dc On-state Current 10mA 2mA Off-state Voltage 5V dc - Off-state Current - 1.5mA Output Specification Max. Min.
ArmorBlock MaXum 2 Input with Alarm/ 2 Output Module Series B 13 2 Input with Alarm / 2 Output Module - Cat. No. 1792D-2BVA2D Dimensions (assembled to base) inches - (Millimeters) Environmental Conditions Operational Temperature Storage Temperature Relative Humidity Shock Operating Non-operating Vibration Conductors 1.9H x 2.7W x 4.72D (48.26)H x (68.
ArmorBlock MaXum 2 Input with Alarm/ 2 Output Module Series B Hazardous Location Approval The following information applies only to products marked with Hazardous Location Approval, when operating in hazardous locations: Products marked “CL I, DIV 2, GP A, B, C, D” are suitable for use in Class I Division 2 Groups A, B, C, D, Hazardous Locations and nonhazardous locations only. Each product is supplied with markings on the rating nameplate indicating the hazardous location temperature code.
ArmorBlock MaXum 2 Input with Alarm/ 2 Output Module Series B WARNING ! 15 When used in a Class I, Division 2, hazardous location, this equipment must be mounted in a suitable enclosure with proper wiring method that complies with the governing electrical codes.
AVERTISSEMENT ! AVERTISSEMENT ! Utiliser des fils d’alimentation qui conviennent à une température de 30°C au-dessus de la température ambiante. Pour une utilisation en environnement de classe i, division 2 dangereux, cet equipement doit etre monte dans un boitier avec un cablage approprie conforme aux normes electriques en vigueur. This product has been tested at an Open DeviceNet Vendor Association, Inc. (ODVA) authorized independent test laboratory and found to comply with ODVA Conformance Test.