Safety Modules Owner manual
94 Rockwell Automation Publication 1791ES-UM001D-EN-P - May 2013
Appendix C Configuration Reference Information
Table 30 - Test Output Parameters
Parameter Name Value Description Default
Test Output Mode Not Used An external device is not connected. Not Used
Standard The output is connected to a standard device.
Pulse Test A contact output device is connected. Use in combination with a safety input.
Power Supply The power supply of a Safety Sensor is connected. The voltage supplied to I/O
power (V, G) is output from the test output terminal.
Muting Lamp Output (Terminal T3 or
T7 only)
An indicator is connected and turned ON to detect broken lines in an external
indicator.
Not Used An external output devices is not connected.
Safety When the output is ON, the test pulse is not output (remains ON).
Safety Pulse Test By using this function, short-circuits between output signal lines and the
power supply (positive side) and short-circuits between output signal lines
can be detected.
Single Channel Use as single channel.
Dual-channel Use as dual-channel. When both channels are normal, outputs can be turned
ON.
Table 31 - Safety Output Parameters
Parameter Name Value Description Default
Output Point Mode Not Used An external output devices is not connected. Not Used
Safety When the output is ON, the test pulse is not output (remains ON).
Safety Pulse Test By using this function, short-circuits between output signal lines and the
power supply (positive side) and short-circuits between output signal lines
can be detected.
Output Point Operation Type Single Channel Use as single channel. Dual-channel
Dual-channel Use as dual-channel. When both channels are normal, outputs can be turned
ON.