Installation Instructions DeviceNet Digital Base D-Shell Block CompactBlock LDX I/O Catalog Numbers 1790D-16BV0, 1790D-8BV8V, 1790D-8BV8B, 1790D-0B16, 1790D-0V16, 1790D-0W6, Series A Topic Page Important User Information 2 Prevent Electrostatic Discharge 3 Environment and Enclosure 3 Power Supply 4 North American Hazardous Location Approval 5 Before You Begin 6 Install the Base Block 6 Set the Node Address 7 Mount the Base Block 8 Mount the Optional Expansion Block 9 Wire the TD-Shel
DeviceNet Digital Base D-Shell Block CompactBlock LDX I/O Important User Information Solid state equipment has operational characteristics differing from those of electromechanical equipment. Safety Guidelines for the Application, Installation and Maintenance of Solid State Controls (publication SGI-1.1 available from your local Rockwell Automation sales office or online at http://literature.rockwellautomation.
DeviceNet Digital Base D-Shell Block CompactBlock LDX I/O 3 Prevent Electrostatic Discharge ATTENTION This equipment is sensitive to electrostatic discharge, which can cause internal damage and affect normal operation. Follow these guidelines when you handle this equipment: • Touch a grounded object to discharge potential static. • Wear an approved grounding wriststrap. • Do not touch connectors or pins on component boards. • Do not touch circuit components inside the equipment.
DeviceNet Digital Base D-Shell Block CompactBlock LDX I/O Power Supply ATTENTION 1790D-0V16, 1790D-0B16 To comply with the CE Low Voltage Directive (LVD), the DeviceNet network and outputs must be powered from a source compliant with Safety Extra Low Voltage (SELV) or Protected Extra Low Voltage (PELV). To comply with UL restrictions, the DeviceNet network and outputs must be powered from a source compliant with Class 2 or Limited Voltage/Current.
DeviceNet Digital Base D-Shell Block CompactBlock LDX I/O 5 North American Hazardous Location Approval The following information applies when operating this equipment in hazardous locations. Informations sur l’utilisation de cet équipement en environnements dangereux. Products marked CL I, DIV 2, GP A, B, C, D are suitable for use in Class I Division 2 Groups A, B, C, D, hazardous locations and nonhazardous locations only.
DeviceNet Digital Base D-Shell Block CompactBlock LDX I/O Before You Begin Read this section about CompactBlock LDX I/O block requirements. Current functions of CompactBlock LDX I/O blocks require the current, modular electronic data sheet (EDS) file for RSNetWorx for DeviceNet software, version 3.0 or later. These files are available online at www.ab.com/networks/eds/. EDS files for blocks with matching catalog numbers for both D-Shell and terminal block versions are the same.
DeviceNet Digital Base D-Shell Block CompactBlock LDX I/O 7 Set the Node Address When setting the node address on the base block, note that each base block comes with its internal program set for node address 63. To reset the node address, adjust the switches on the front of the base block. The two switches are most significant digit (MSD) and least significant digit (LSD). You can set switches between 00 and 63. The base block reads the rotary switches only when power is applied.
DeviceNet Digital Base D-Shell Block CompactBlock LDX I/O Mount the Base Block Mount the base block to a panel or DIN rail. We recommend that you ground the panel or DIN rail before mounting the block. IMPORTANT The analog base module can accommodate a maximum of two digital expansion modules. Mount on a Panel For panel mounting, use these steps. 95 mm (3.74 in.) 41 mm (1.6 in.) Expansion Cover 44153 1 . Place the block against the panel where you want it mounted. 2.
DeviceNet Digital Base D-Shell Block CompactBlock LDX I/O 9 4. Remove the block and drill two holes in the panel to accommodate each of the mounting screws. 5. Replace the block on the panel and place a screw through each of the two mounting holes. 6. Tighten the screws until the block is firmly in place. Mount on DIN Rail For DIN-rail mounting, use these steps. 1 . Hook the top slot of the base block over the DIN rail. Locking Lever 44154 2.
DeviceNet Digital Base D-Shell Block CompactBlock LDX I/O Beginning with the base block, mount your expansion block either horizontally or vertically. Horizontal Mounting Vertical Mounting The longer expansion cable (1790-15CMCBL) provides for up to 7 cm (2.76 in.) of space in between blocks. 44155 • To mount horizontally (left to right), add the expansion block in an end-to-end configuration.
DeviceNet Digital Base D-Shell Block CompactBlock LDX I/O 11 See the figures for wiring information.
DeviceNet Digital Base D-Shell Block CompactBlock LDX I/O 1790D-8BV8B Input/Output Block Wiring Diagram I1 COM0 I0 19 18 37 17 16 35 36 I3 I2 15 34 I4 13 14 33 I5 12 31 32 I7 I6 11 30 O0 O2 O4 O6 COM2 O1 O3 O5 O7 9 10 28 29 8 27 7 26 5 6 24 25 3 4 22 23 1 2 20 21 COM1 COM1 COM1 COM1 COM1 COM3 COM3 COM3 COM3 COM1 COM1 COM1 COM1 COM3 COM3 COM3 COM3 COM3 44167 For sinking inputs, wire Com 1 to Field Power (+) 24V dc and Com 0 to Field Power (-) GND.
DeviceNet Digital Base D-Shell Block CompactBlock LDX I/O 13 1790D-0V16 Output Block Wiring Diagram O7 O8 COM0 O1 O10 O12 O3 O14 O5 O6 COM2 O0 O9 O11 O2 O13 O4 O15 19 18 37 17 16 35 36 15 34 13 14 33 12 30 31 32 11 9 10 28 29 8 27 7 26 5 6 24 25 3 4 22 23 1 2 20 21 COM1 COM0 COM0 COM0 COM0 COM2 COM2 COM2 COM2 COM0 COM0 COM0 COM0 COM3 COM2 COM2 COM2 COM2 44169 For sinking outputs, wire Com 0 and Com 2 to Field Power (+) 24V dc, and Com 1 and Com 3 to Field Power (-) GND.
DeviceNet Digital Base D-Shell Block CompactBlock LDX I/O Connect the DeviceNet Cable Follow these procedures to connect the DeviceNet cable to the base block. We do not supply the DeviceNet connector with the base block. You must purchase the connector separately. These are the types of connectors you order directly from Rockwell Automation.
DeviceNet Digital Base D-Shell Block CompactBlock LDX I/O 15 1 . Connect the DeviceNet wiring (drop line) to one of the DeviceNet connectors as shown in the figure, noting that a color-coded wiring diagram is printed next to the connector on the left side of the base block. V+ Red Drain/Shield V- Black Can_H White Can_L Blue V+ Red Can_H White Wiring Diagram for 1799-DNETCON Connector Drain/Shield Can_L Blue Wiring Diagram for 1799-DNC5MMS Connector V- Black 2.
DeviceNet Digital Base D-Shell Block CompactBlock LDX I/O Interpret the LED Indicators Read this section for information about how to interpret block LED indicators and related procedures. For a module status indicator that is flashing red, refer to the cable break procedure section. The base block has the following indicators. • Block status • Network status • I/O status Indication Probable Cause Recommended Action Solid Red Unrecoverable fault in base unit. Replace base block.
DeviceNet Digital Base D-Shell Block CompactBlock LDX I/O 17 Indication Probable Cause Recommended Action Solid Green The module is operating in a normal condition, and the module is online with connections in the established state. As a group 2 module, the module is allocated to a master. None. Flashing Green The module is online with no connections in the established state. Establish connections to other nodes. As a group 2 module, allocate the module to a master. Off No power.
DeviceNet Digital Base D-Shell Block CompactBlock LDX I/O Cable Break Procedure A cable break in any location between either of the following produces data of 1 in the data table for all inputs down stream of the cable break. • Base and digital input expansion module • Digital input expansion module and another digital input expansion module All digital-expansion inputs turn on if the expansion cable is removed. No status is in the produced assembly.
DeviceNet Digital Base D-Shell Block CompactBlock LDX I/O 19 Specifications IMPORTANT Input and output wiring must be in accordance with Class 1, Division 2 wiring methods and in accordance with the authority having jurisdiction.. 1790D-16BVO Universal dc Input Base Block Attribute Value Inputs per Module 16 point, sinking or sourcing On-state Voltage 9.6V dc min, 24V dc nom, 28.8V dc max Off-state Voltage 5.0V dc max On-state Current 8 mA max per channel @ 28.8V dc Input Impedance, Nom 4.
DeviceNet Digital Base D-Shell Block CompactBlock LDX I/O 1790D-OW6 ac/dc Relay Output Block Attribute Value Output Delay Time, On to Off, Max 10 ms Output Delay Time, Off to On, Max 10 ms Relay Coil Power Dissipation 1.7 W @ 28.8V dc l Isolation Voltage 50V dc (continuous), reinforced insulation type, tested at 1250V ac for 60 s, I/O to system 1790D-8BV8V, 1790D-8BV8B dc Input/Output Combination Base Block Attribute Value Field Power Dissipation 3.22 W @ 28.
DeviceNet Digital Base D-Shell Block CompactBlock LDX I/O 21 1790D-8BV8V, 1790D-8BV8B dc Input/Output Combination Base Block Attribute Value On-state Current, Min 1 mA per channel Off-state Leakage, Max 0.5 mA Output Signal Delay, Off to On, Max 0.5 ms Output Signal Delay, On to Off, Max 1.0 ms Output Current Rating 0.5 A max per output 4.
DeviceNet Digital Base D-Shell Block CompactBlock LDX I/O Environmental Specifications Common To All Base Blocks in This Publication Attribute Value North American Temp Code T5 Operating Temperature IEC 60068-2-1 (Test Ad, Operating Cold), IEC 60068-2-2 (Test Bd, Operating Dry Heat), IEC 60068-2-14 (Test Nb, Operating Thermal Shock) 0...55 °C (32...
DeviceNet Digital Base D-Shell Block CompactBlock LDX I/O 23 Environmental Specifications Common To All Base Blocks in This Publication Attribute Value Enclosure Type Rating None (open-style) Mounting DIN rail or panel Dimension 52 x 104 x 42 mm (2.03 x 4.07 x 1.64 in.) Weight 0.1 kg (0.
Certifications Attribute Certification(1) (when product is marked) (1) Value 1790D-OV16, 1790D-OB16, 1790D-8BV8V, 1790D-8BV8B, 1790D-16BV0, 1790D-0W6 c-UL-us UL Listed Industrial Control Equipment, certified for U.S. and Canada. See UL File E65584. c-UL-us UL Listed for Class I, Division 2, Group A,B,C,D Hazardous Locations, certified for U.S. and Canada. See UL File E194810. European Union 89/336/EEC EMC Directive,compliant with: EN 50082-2; Industrial Immunity EN 61326; Meas./Control/Lab.