User manual
Calculating Program Timing
Chapter 9
9-12
Category Words of
Memory
1
Time (µs)
Integer or
Floating Point
False
Time (µs)
Floating point
True
Time (µs)
Integer
True
TitleCode
File COP copy 88 + 2.7W 104 + 3.8W 20 47
File
COP
copy
counter, timer, and control
88
+
2
.
7W
98 + 5.8W
104
+
3
.
8W
20
47
FLL fill 81 + 2/.1 W 100 + 3.1W 15
counter, timer, and control 97 + 4.4W
Shift Register BSL bit shift left 74 + 3.4W
57
BSR bit shift right 78 + 3.0W
FFL FIFO load 54 44
FFU FIFO unload 68 + 3.2W 46
Diagnostic FBC file bit compare
611
0 mismatch 75 + 6W
31
1 mismatch 130 + 6W
2 mismatches 151 + 6W
DDT diagnostic detect
0 mismatch 71 + 6W
31
1 mismatch 150 + 6W
2 mismatches 161 + 6W
Zone Control MCR master control 12 18 1
Immediate I/O IIN immediate input
23
local 196
16
remote 204
IOT immediate output
local 202
16
remote 166
Sequencer SQI sequencer input 57 14 59
SQL sequencer load 55 42 47
SQO sequencer output 77 42 59
Jump and Subroutine JMP jump 45 15 23
JSR jump to subroutine
SBR 0 parameters 56
15
23
1 parameter 91 35
add per parameter 21
RET return from sub.
0 parameters 48
13
1
1 parameter 70 23
add per parameter 21
LBL label 12 12 3
W =
number of elements acted on per scan
1
Use
the smaller number if all addresses are below word 4096; use the larger number if all addresses are above 4096.