2-6 Connect a Computer to the ControlNet Network
4. Configure the card.
You can specify any slot number greater than 0 for the communication card. 
RSLinx software resides in slot 0. 
By creating the card in the virtual chassis, you configure the communication 
driver information needed by the SoftLogix controller. DO NOT use RSLinx 
software to install the ControlNet communication driver to the same card; 
installation through RSLinx software adds the potential for conflicting 
configuration between RSLinx software and the SoftLogix software chassis 
monitor.
Instead, configure a Virtual Backplane driver in RSLinx software. After you 
add the card to the chassis monitor and configure a Virtual Backplane driver, 
you can browse the network by expanding the Virtual Backplane driver and 
then expanding the port on the desired ControlNet communication card. 
Browsing ControlNet through the Virtual Backplane driver provides the same 
functionality as the RSLinx software driver.
The chassis monitor shows the 1784-PCICS card as a virtual module in the 
SoftLogix chassis. The LEDs on the virtual monitor emulate either a 
1756-CN2R or a 1756-CNBR communication module. 
A.Specify the node address on the 
ControlNet network.
B.Enter the label name for the card 
(this is the name you wrote on the 
label of the card to help you identify 
the card from others in the same 
computer).
C. Click Finish.
This chassis monitor has a 
1784-PCICS card installed in slot 2.