User manual
Publication CNET-UM001C-EN-P - November 2005
7-4 Communicate with PanelView and RSView Products
3. Select the local ControlNet communication module type from the Select
Module Type pop-up. The example below uses a 1788-CNC card.
The table ControlNet communication Modules Available Locally lists
the ControlNet communication modules available locally (in the local
chassis, computer or controller) with each Logix5000 controller.
Table 7.1 ControlNet communication Modules Available Locally
4. Configure the local ControlNet communication module.
For more information on how to configure ControlNet communication
modules, see the chapter Configure a ControlNet Module.
A.Select the local ControlNet
communication module.
B.Click OK.
If You Are Using This Logix5000
Controller
You Can Use This ControlNet
Communication Module Locally
CompactLogix 1769-L32C, 1769-L35CR have a built-in
ControlNet port
ControlLogix 1756-CN2, 1756-CN2R
1756-CNB, 1756-CNBR
FlexLogix 1788-CNC, 1788-CNCR, 1788-CNF, 1788-CNFR
SoftLogix 1784-PCIC (unscheduled data only), 1784-PCICS,
1784-PKTCS (unscheduled data only)