Troubleshooting guide

Hardware configuration 29
Interrupt
TIP
WINtelligent LINX does not use the 1784-KT interrupt. However, you
may be using other software that does use the 1784-KT interrupt. In
that case, set the interrupt as recommended for that software. The
1784-KT interrupt may conflict with other devices in your computer as
shown below.
Interrupt May conflict with
3COM2
4COM1
5LPT2
7LPT1
Base Address
Address Switch 1 Switch 2 Switch 3 Switch 4 Switch 5 Switch 6
A000 ON ON ON OFF ON OFF
A400 OFF ON ON OFF ON OFF
A800 ON OFF ON OFF ON OFF
AC00 OFF OFF ON OFF ON OFF
B000 ON ON OFF OFF ON OFF
B400 OFF ON OFF OFF ON ON
B800 ON OFF OFF OFF ON OFF
C000 ON ON ON ON OFF OFF
C400OFFONONONOFFOFF
C800 ON OFF ON ON OFF OFF
CC00OFFOFFONONOFFOFF
D000 ON ON OFF ON OFF OFF
D400 OFF ON OFF ON OFF OFF
D800 ON OFF OFF ON OFF OFF