Installation Instructions Owner's manual

Stratix 6000 Ethernet Managed Switches 17
Rockwell Automation Publication 1783-IN004B-EN-P - June 2014
c. From the Ethernet Protocol (TCP/IP) Properties menu, change the
IP address to 192.168.1.3 and Subnet mask to 255.255.255.0.
2. Connect to the switch via a Web browser by using these steps.
a. Open a browser window.
b. Enter the default IP address of 192.168.1.1 in the address bar, press
Enter, and note the following defaults:
User name should be left blank.
Password is PASSWORD.
3. Configure the switch.
You can get complete configuration instructions by clicking the link to
view the embedded manual.
4. If the switch is to scan in a Logix 5000™ program, refer to the appropriate
section of your embedded manual.