5. Do one of the following:
• To translate a single address for a device on the private subnet that
needs to communicate on the public subnet, complete the fields below.
• To translate a range of addresses for devices on the private subnet that
need to communicate on the public subnet, complete the fields below.
Field Description
Type of Entry Choose Single. This is the default value.
Starting Private IP Address Type the existing address for the device on the private subnet.
Starting Public IP Address Type a unique public address to represent the device.
Effective Private Addresses Displays the existing address for the device on the private subnet that is
configured for translation.
If blank, verify that the values in the fields above are valid.
Effective Public Addresses Displays the unique public address to represent the device.
If blank, verify that the values in the fields above are valid.
Field Description
Type of Entry Choose Range.
Starting Private IP Address Type the existing starting address for the device on the private subnet.
Starting Public IP Address Type a unique, starting public address to represent the devices.
Range Type the number of addresses to include in the range.
Valid values: 1…128
Default value = 1
IMPORTANT: Each address in the range counts as one translation entry.
The switch supports a maximum of 128 translation entries.
Effective Private Addresses Displays the range of existing addresses for devices on the private subnet
that are configured for translation.
If blank, verify that the values in the fields above are valid.
Effective Public Addresses Displays the range of unique public addresses to represent the devices.
If blank, verify that the values in the fields above are valid.