User Manual User guide

Rockwell Automation Publication 1783-UM004E-EN-P - June 2014 199
Manage the Switch via the Studio 5000 Environment Chapter 5
Switch Status
From the Switch Status tab, you can view various status parameters for the switch.
Table 31 - Switch Status Tab Fields
Field Description
Active Alarms Displays one of these values:
None
Port alarm
Dual Mode Power Supply alarm
Primary Temperature alarm
Major Alarm Relay Displays one of these values:
Open
Closed
Active Faults Displays one of these values:
None
Port fault
Hardware fault
If the port and hardware faults are active, the Hardware fault status appears.
Traffic Threshold Exceeded on Any Port Displays a yes or no value indicating whether the current unicast, multicast, and broadcast thresholds have been
exceeded on any port.
To view the status of the active ports, click the Port Status tab. To view the threshold values, click the Advanced -
Port Threshold tab.
Switch Uptime Displays the days, hours, and minutes that the switch has been functioning since the last restart.
Switch Temperature Displays the current internal temperature (in degree Celsius) of the switch.
Bandwidth Utilization Displays the total percentage of the switch bandwidth being used.
Power Present on Terminal A Displays a yes or no value indicating whether power is present on Terminal A.
Power Present on Terminal B Displays a yes or no value indicating whether power is present on Terminal B.
Number of Active Multicast Groups Displays the number of active multicast groups.
IOS Release Displays the current version of the switch operating system.