Owner's manual

Block Format Instructions
Chapter 10
102
Turn the keyswitch to the program position (PROG).
As we stated in chapter 4, you must expand the data table to provide additional
space for files. To do this:
KEY
DISPLAY
SEARCH
No display is on the screen
50
DATA TABLE CONFIGURATION
NUMBER OF 128-WORD D.T. BLOCKS 02
NUMBER OF INPUT/OUTPUT RACKS
NUMBER OF T/C (if applicable)
DATA TABLE SIZE
2
104
256
The above chart shows a factory configured data table.
The following chart will help you adjust your data table size:
Enter Data
T
able Size
01
02
03
04
05
10
15
128
256
384
512
640
1280
1920
After you have adjusted the data table, press [CANCEL COMMAND] and we’ll
continue.
NOTE: Other industrial terminal commands are summarized in the Quick
Reference section of this manual.
This is your end result:
EN
File to File Move
Counter Addr:
Position:
File Length:
200
001
007
DN
File A:
File R:
Rate Per Scan
0400-0406
0500-0507
007
112
05
200
17
200
15
Before you begin: