3–18 Status Word/Bit Descriptions
Publication
1771-6.5.126 – March 1998
Notes: For [ ] engineering units, see page 2.
Word
Bit Description
SYS10 B05 Hold Profile High Cavity Pressure
B06 Pre-decompress Movement High Ram (Screw) Pressure
B07 Plastication Profile High Ram (Screw) Pressure
B08 Post-decompress Movement High Ram (Screw) Pressure
B09-15 RFU
SYS11 Overtravel Alarm Status (Latched)
Module latches alarm bits on each false-to-true transition of the corresponding real-time alarm bit in SYS07.
Module unlatches all 16 bits when it receives a false-to-true transition of DYC03-B09. You can inhibit each bit by setting
its associated alarm setpoint to zero.
This bit
latched ON:
when the module detected this alarm:
B00 Ram (Screw) Overtravel at Bottom
B01 Ram (Screw) Overtravel at Top
B02-07 RFU
B08-B15 Reserved for the module. Do not use.
SYS12 Alarm Status for Loss of Input Sensor (Latched)
Module latches alarm bits on each false-to-true transition of the corresponding real-time alarm bit in SYS08.
Module unlatches all 16 bits when it receives a false-to-true transition of DYC03-B09.
This bit
latched ON:
when the module detected this alarm
B00 Loss of Ram (Screw) Position Sensor (except when MCC64 is SET)
B01 Loss of Ram (Screw) Pressure Sensor (except when MCC64 is SET)
B02-05 RFU
B06 Loss of Screw RPM Sensor (except when MCC64 is SET)
B07 Loss of Cavity Pressure Sensor (except when MCC64 is SET)
B08-B15 RFU
SYS13 Action-execution Command Errors
B00
= 0 Normal
= 1 Jog Command Error
The module latches this bit when SYS15-B01 is RESET and one of the following is true:
DYC01-B09 is SET
DYC01-B10 is SET
Y 1- 11 i T
D
Y
C0
1-
B
11 i
s
SE
T
DYC01-B12 is SET
DYC01-B13 is SET
DYC01-B14 is SET
DYC01-B15 is SET
Module unlatches this bit when it decodes a valid DYC Block with any SET action execution bit other than listed above.
B01-04 RFU
B05 = 0 Normal
= 1 Injection Profile Command Error
The module latches this bit when both of the following are true:
DYC02-B04 is SET
SYS15-B08 is RESET
The module unlatches this bit when it decodes a valid Dynamic Command Block with any SET action execution bit
other than DYC02-B04.
B06 = 0 Normal
= 1 Pack Profile Command Error
The module latches this bit when both of the following are true:
DYC02-B05 is SET
the Injection Profile completes
The module unlatches this bit when it decodes a valid Dynamic Command Block with any SET action execution bit
other than DYC02-B05.