Manual
3–14 Status Word/Bit Descriptions
Publication
1771-6.5.126 – March 1998
Notes: For [ ] engineering units, see page 2.
Word Description
RLS37 Plastication Segment 8
RLS38 Plastication Segment 9
RLS39 Plastication Segment 10
RLS40 Plastication Segment 11
RLS41 - 64 RFU
Bit-mapped Status Words
Word Bit Description
SYS01
B00-B07 Block ID = 00000001
Y1
B08-B15 Power-up Status
B08 = 0 The module Wants Complete Download
= 1 Valid MCC on Board
Jog Execution Status
B09 = 0 Normal
= 1 Executing Screw Rotate Jog
The module sets this bit when responding to command bit DYC01-B09 = 1 and sets its outputs to JGC09–12.
B10 = 0 Normal
= 1 Executing Ram (Screw) Jog Forward
The module sets this bit when responding to command bit DYC01-B10 = 1 and sets its outputs to JGC17–20
B11 = 0 Normal
= 1 Executing Ram (Screw) Jog Reverse
The module sets this bit when responding to command bit DYC01-B11 = 1 and sets its outputs to JGC25–28
B12-15 RFU
SYS02
Profile Execution Status
The module sets each bit, SYS02 - B00 through B14 when:
it completes the profile or movement, or
it receives a new action execution command that terminates the profile or movement
The module resets each bit, SYS02 - B00 through B14 when:
it starts the profile or movement, or
it receives a valid DYC with DYC03-B10 SET
B00-03 RFU
B04 SYS02.B04 for QI(A) SYSB02.B04 for QI(B)
= 0 Normal
= 1 Injection Profile Complete
Important: The QI module will not set this bit during suspended injection.
B05 = 0 Normal
= 1 Pack Profile Complete
B06 = 0 Normal
= 1 Hold Profile Complete
B07 = 0 Normal
= 1 Pre-decompression Movement Complete
B08 = 0 Normal
= 1 Plastication Profile Complete
B09 = 0 Normal
= 1 Post-decompression Movement Complete
B10-14 RFU
Module Busy Status
B15 = 0 Normal
= 1 No Action in Progress
The module resets this bit when it is performing one of the following:
executing a profile or decompression movement
holding its outputs at any End of phase values
executing any jog movement
SYS – System Status Block