Manual
2–14 Command Word/Bit Descriptions
Publication
1771-6.5.126 – March 1998
Notes: For [ ] engineering units, see page 2.
Word
Bit Description
HPC04 B04-07 RFU
ERC Enabled/Disabled Selection
B08 = 0 Ram Press/Time Pack Profiles ERC On
= 1 Ram Press/Time Pack Profiles ERC Off
B09 = 0 Cav Press/Time Pack Profiles ERC On
= 1 Cav Press/Time Pack Profiles ERC Off
B10 = 0 Ram Press/Time Hold Profiles ERC On
= 1 Ram Press/Time Hold Profiles ERC Off
B11 = 0 Cav Press/Time Hold Profiles ERC On
= 1 Cav Press/Time Hold Profiles ERC Off
B12-15 RFU
HPC05 - 08 RFU
Pack Profile Setpoints
Word Description
HPC09 Pack Segment 1 Cavity Pressure Setpoint [04] If you select Cav Press/Time profile execution, the module controls cavity pressure
to this setpoint after starting the Pack Profile for time period specified by HPC11.
HPC10 Pack Segment 1 Ram (Screw) Pressure Setpoint [01] If you select Ram Press/Time profile execution, the module controls ram
(screw) pressure to this setpoint after starting the Pack Profile for time period specified by HPC11.
HPC11 Pack Segment 1 Time Setpoint [21] The module controls the selected process pressure to the setpoint HPC09 or HPC10 for this
time period beginning with initiation of the Pack Profile.
HPC12 Pack Segment 2 Cavity Pressure Setpoint [04] If you select Cav Press/Time profile execution, the module controls cavity pressure
to this setpoint at completion of segment 1 for time period specified by HPC14.
HPC13 Pack Segment 2 Ram (Screw) Pressure Setpoint [01] If you select Ram Press/Time profile execution, the module controls ram
(screw) pressure to this setpoint at completion of segment 1 for time period specified by HPC14.
HPC14 Pack Segment 2 Time Setpoint [21] The module controls the selected process pressure to the setpoint HPC12 or HPC13 for this
time period beginning at completion of Segment 1.
HPC15 Pack Segment 3 Cavity Pressure Setpoint [04] If you select Cav Press/Time profile execution, the module controls cavity pressure
to this setpoint at completion of segment 2 for time period specified by HPC17.
HPC16 Pack Segment 3 Ram (Screw) Pressure Setpoint [01] If you select Ram Press/Time profile execution, the module controls ram
(screw) pressure to this setpoint at completion of segment 2 for time period specified by HPC17.
HPC17 Pack Segment 3 Time Setpoint [21] The module controls the selected process pressure to the setpoint HPC15 or HPC16 for this
time period beginning at completion of Segment 2.
HPC18 Pack Segment 4 Cavity Pressure Setpoint [04] If you select Cav Press/Time profile execution, the module controls cavity pressure
to this setpoint at completion of segment 3 for time period specified by HPC20.
HPC19 Pack Segment 4 Ram (Screw) Pressure Setpoint [01] If you select Ram Press/Time profile execution, the module controls ram
(screw) pressure to this setpoint at completion of segment 3 for time period specified by HPC20.
HPC20 Pack Segment 4 Time Setpoint [21] The module controls the selected process pressure to the setpoint HPC18 or HPC19 for this
time period beginning at completion of Segment 3.
HPC21 Pack Segment 5 Cavity Pressure Setpoint [04] If you select Cav Press/Time profile execution, the module controls cavity pressure
to this setpoint at completion of segment 4 for time period specified by HPC23.
HPC22 Pack Segment 5 Ram (Screw) Pressure Setpoint [01] If you select Ram Press/Time profile execution, the module controls ram
(screw) pressure to this setpoint at completion of segment 4 for time period specified by HPC23.
HPC23 Pack Segment 5 Time Setpoint [21] The module controls the selected process pressure to the setpoint HPC21 or HPC22 for this
time period beginning at completion of Segment 4.
Pack Profile Offsets
Word Description
HPC24 Pack Profile Cavity Pressure Offset [04] If you select Cav Press/Time profile execution , the module applies this entry (after reading
the sign bit) to each cavity pressure profile setpoint.
HPC25 Pack Profile Ram (Screw) Pressure Offset [01] If you select Ram Press/Time profile execution, the module applies this entry (after
reading the sign bit) to each ram (screw) pressure profile setpoint.