Manual
2–9Command Word/Bit Descriptions
Publication
1771-6.5.126 – March 1998
DYC
Word Bit Description
DYC07 Process Trace Commands
B00 Process trace data collection inhibited (examined at beginning of injection phase)
B01 Return injection position trace data in next PTS block
B02 Return trace #1 data in next PTS block
B03 Return trace #2 data in next PTS block
B04 Return trace #3 data in next PTS block
B05 Return trace #4 data in next PTS block
B06-14 RFU
B15 Return phase/segment start information in next PTS block
DYC08 Process Trace Data Block Request
B00 Return trace data points 1 to 50 in next PTS block
B01 Return trace data points 51 to 100 in next PTS block
B02 Return trace data points 101 to 150 in next PTS block
B03 Return trace data points 151 to 200 in next PTS block
B04 Return trace data points 201 to 250 in next PTS block
B05 Return trace data points 251 to 300 in next PTS block
B06 Return trace data points 301 to 350 in next PTS block
B07 Return trace data points 351 to 400 in next PTS block
B08-15 RFU
Direct Set-output Values
The module sets its outputs to the following values when responding
to command bit DYC01-B08 = 1. The module uses ramp rates
DYC17-20 and DYC25-28 when moving the outputs to these values
after DYC01-B08 is SET, and will also use the ramps when one of
DYC09-12 is changed while DYC01-B08 is SET.
Word Description
DYC09 Output #1 Direct Set-output Value [19]
DYC10 Output #2 Direct Set-output Value [19]
DYC11 Output #3 Direct Set-output Value [19]
DYC12 Output #4 Direct Set-output Value [19]
DYC13-16 RFU
Direct Set-output Ramp Rates
Word Description
DYC17 Output #1 Accel Ramp Rate for Direct Set-output Moves [20]
DYC18 Output #2 Accel Ramp Rate for Direct Set-output Moves [20]
DYC19 Output #3 Accel Ramp Rate for Direct Set-output Moves [20]
DYC20 Output #4 Accel Ramp Rate for Direct Set-output Moves [20]
DYC21-24 RFU
DYC25 Output #1 Decel Ramp Rate for Direct Set-output Moves [20]
DYC26 Output #2 Decel Ramp Rate for Direct Set-output Moves [20]
DYC27 Output #3 Decel Ramp Rate for Direct Set-output Moves [20]
DYC28 Output #4 Decel Ramp Rate for Direct Set-output Moves [20]
DYC29-60 RFU