Manual
1–10 Abbreviated Command and Status Blocks
Publication
1771-6.5.126 – March 1998
Profile Tuning Constants
PKC49
N44:165 Proportional gain, ram (screw) pressure control
PKC50 N44:166 Integral gain, ram (screw) pressure control
PKC51 N44:167 Derivative gain, ram (screw) pressure control
PKC52 N44:168 Proportional gain, cavity pressure control
PKC53 N44:169 Integral gain, cavity pressure control
PKC54 N44:170 Derivative gain, cavity pressure control
Setpoints for Profile Pressure Alarms
PKC55-56 N44:171-172 RFU
PKC57 N44:173 High ram (screw) pressure alarm
PKC58 N44:174 High cavity pressure alarm
PKC59-64 N44:175-180 RFU
Word Pro-Set Address Description
Bit-mapped Control Words
PLC01 B38:24 Block ID 00000000 00001110
PLC02 B38:25 Selected valve configurations
PLC03-04 B38:26-27 RFU
Expert Response Compensation Percentage
PLC05 N44:361 ERC % minimum RPM
PLC06 N44:362 ERC % minimum pressure
PLC07 N44:363 RFU
Watchdog Timer
PLC08 N44:364 Profile timer preset
Set-output Values for Unselected Valves (During Profile)
PLC09 N44:365 Output #1
PLC10 N44:366 Output #2
PLC11 N44:367 Output #3
PLC12 N44:368 Output #4
PLC13-16 N44:369-372 RFU
Acceleration Ramp Rates
PLC17 N44:373 Output #1
PLC18 N44:374 Output #2
PLC19 N44:375 Output #3
PLC20 N44:376 Output #4
PLC21-24 N44:377-380 RFU
Deceleration Ramp Rates
PLC25 N44:381 Output #1
PLC26 N44:382 Output #2
PLC27 N44:383 Output #3
PLC28 N44:384 Output #4
PLC29-32 N44:385-388 RFU
End of Profile Set-output Values
PLC33 N44:389 Output #1
PLC34 N44:390 Output #2
PLC35 N44:391 Output #3
PLC36 N44:392 Output #4
PLC37-40 N44:393-396 RFU
PLC – Plastication
Configuration Block