Manual

1–9Abbreviated Command and Status Blocks
Publication
1771-6.5.126 – March 1998
Cavity Pressure Sensor Configuration
MCC57
N40:53 Minimum pressure
MCC58 N40:54 Maximum pressure
MCC59 N40:55 Analog signal @ min pressure
MCC60 N40:56 Analog signal @ max pressure
MCC61 N40:57 High pressure alarm setpoint
MCC62 N40:58 Time delay for pressure alarms
MCC63 N40:59 Switchover time delay, input 3: cavity pressure/RPM
MCC64 N40:60 Number of input samples for loss-of-sensor alarms
Word Pro-Set Address Description
Bit-mapped Control Words
PKC01 B38:8 Block ID 00000000 00001010
PKC02 B38:9 Selected valve configurations
PKC03-04 B38:10-11 RFU
Expert Response Compensation Percentage
PKC05 N44:121 ERC % minimum cavity pressure
PKC06 N44:122 ERC % minimum ram pressure
PKC07-08 N44:123-124 RFU
Set-output Values for Unselected Valves (During Profile)
PKC09 N44:125 Output #1
PKC10 N44:126 Output #2
PKC11 N44:127 Output #3
PKC12 N44:128 Output #4
PKC13-16 N44:129-132 RFU
Acceleration Ramp Rates
PKC17 N44:133 Output #1
PKC18 N44:134 Output #2
PKC19 N44:135 Output #3
PKC20 N44:136 Output #4
PKC21-24 N44:137-140 RFU
Deceleration Ramp Rates
PKC25 N44:141 Output #1
PKC26 N44:142 Output #2
PKC27 N44:143 Output #3
PKC28 N44:144 Output #4
PKC29-40 N44:145-156 RFU
Ram (Screw) Pressure Control Limits
PKC41 N44:157 Minimum limit
PKC42 N44:158 Maximum limit
PKC43 N44:159 % output for minimum
PKC44 N44:160 % output for maximum
Cavity Pressure Control Limits
PKC45 N44:161 Minimum limit
PKC46 N44:162 Maximum limit
PKC47 N44:163 % output for minimum
PKC48 N44:164 % output for maximum
PKC – Pack
Configuration Block