Manual
1–7Abbreviated Command and Status Blocks
Publication
1771-6.5.126 – March 1998
Setpoints for Injection Profile (continued)
IPC41
N44:97 Segment 9 velocity
IPC42 N44:98 Segment 9 pressure
IPC43 N44:99 End of Segment 9 position
IPC44 N44:100 Segment 9 time
IPC45 N44:101 Segment 10 velocity
IPC46 N44:102 Segment 10 pressure
IPC47 N44:103 End of Segment 10 position
IPC48 N44:104 Segment 10 time
IPC49 N44:105 Segment 11 velocity
IPC50 N44:106 Segment 11 pressure
Profile Offsets
IPC51 N44:107 Velocity Profile
IPC52 N44:108 Pressure Profile
IPC53 N44:109 RFU
Setpoints for Suspended Injection
IPC54 N44:110 Closed-loop velocity setpoint during suspended injection
IPC55 N44:111 Closed-loop pressure setpoint during suspended injection
IPC56 N44:112 Screw position (of own) to start suspension
Pressure Limiting Values
IPC57 N44:113 Ram (Screw) pressure, LimVel/Pos profile
IPC58 N44:114 Ram (Screw) position to begin pressure limiting
IPC59 N44:115 Time delay for change in algorithm
Transition (Transfer) Values
IPC60 N44:116 Time
IPC61 N44:117 Ram (Screw) position
IPC62 N44:118 Ram (Screw) pressure
IPC63 N44:119 Cavity pressure
Transition (Transfer) Pressure Inhibit
IPC64 N44:120 Ram (Screw) position
Word Pro-Set Address Description
Bit-mapped Control Words
JGC01 B34:36 Block ID 00000000 00000010
JGC02-04 B34:37-39 RFU
Jog Alarm Setpoints
JGC05 N40:61 Screw jog RPM alarm
JGC06 N40:62 Ram jog pressure alarm
JGC07 N40:63 RFU
JGC08 N40:64 RFU
Screw-rotate Jog Set-output Values
JGC09 N40:65 Output #1
JGC10 N40:66 Output #2
JGC11 N40:67 Output #3
JGC12 N40:68 Output #4
JGC13-16 N40:69-72 RFU
JGC – Jog
Configuration Block