Manual
1–5Abbreviated Command and Status Blocks
Publication
1771-6.5.126 – March 1998
Expert Response Compensation Percentage
INC05
N44:1 ERC % minimum velocity
INC06 N44:2 ERC % minimum pressure
INC07, 08 N44:3, 4 RFU
Set-output Values for Unselected Valves (During Profile)
INC09 N44:5 Output #1
INC10 N44:6 Output #2
INC11 N44:7 Output #3
INC12 N44:8 Output #4
INC13-16 N44:9-12 RFU
Acceleration Ramp Rates
INC17 N44:13 Output #1
INC18 N44:14 Output #2
INC19 N44:15 Output #3
INC20 N44:16 Output #4
INC21-24 N44:17-20 RFU
Deceleration Ramp Rates
INC25 N44:21 Output #1
INC26 N44:22 Output #2
INC27 N44:23 Output #3
INC28 N44:24 Output #4
INC29-32 N44:25-28 RFU
End of Profile Set-output Values
INC33 N44:29 Output #1
INC34 N44:30 Output #2
INC35 N44:31 Output #3
INC36 N44:32 Output #4
INC37-40 N44:32-36 RFU
Pressure Control Limits
INC41 N44:37 Minimum limit
INC42 N44:38 Maximum limit
INC43 N44:39 % output for minimum
INC44 N44:40 % output for maximum
Velocity Control Limits
INC45 N44:41 Minimum limit
INC46 N44:42 Maximum limit
INC47 N44:43 % output for minimum
INC48 N44:44 % output for maximum
Profile Tuning Constants
INC49 N44:45 Proportional gain, pressure control
INC50 N44:46 Integral gain, pressure control
INC51 N44:47 Derivative gain, pressure control
INC52 N44:48 Proportional gain, velocity control
INC53 N44:49 Feedforward gain, velocity control
INC54-56 N44:50-52 RFU
Setpoints for Profile Pressure Alarms
INC57 N44:53 High ram (screw) pressure alarm
INC58 N44:54 High cavity pressure alarm
INC59-60 N44:55-56 RFU