Manual
6–2 Module Specifications
Publication
1771-6.5.126 – March 1998
The following table lists process control options.
Phase: Type of Profile: Mode:
Injection phase: 10-step profile with
selectable transition
velocity vs. position
or
velocity vs. position pressure limited
or
injection pressure vs. position
or
injection pressure vs. time
open/closed with ERC
open/closed with ERC
open/closed with ERC
open/closed with ERC
Selectable Transition dependent on:
Time
Ram (screw) pressure
Cavity pressure
or Ram (screw) position
N/A N/A
Pack phase: 5-step profile ram (screw) pressure vs. time
or
cavity pressure vs. time
open/closed with ERC
open/closed with ERC
Hold phase: 5-step profile ram (screw) pressure vs. time
or
cavity pressure vs. time
open/closed with ERC
open/closed with ERC
Plastication phase: 10-step profile backpressure vs. position
or
backpressure vs. time
or
screw RPM vs. position
or
screw RPM vs. time
open/closed with ERC
open/closed with ERC
open/closed with ERC
open/closed with ERC
Alarms Process
Programming
N/A
Control Options P, I, PI, PD, PID, and FF
Expert Response Compensation
Open/Closed Loop
N/A
Process Control Options