Manual

4–25Programming Error Codes
Publication
1771-6.5.126 – March 1998
Error Code
Description
PPC ID = 15
0439 PPC39 is out of range.
if: then:
MCC13 and MCC14 PPC39 must be within 00000 PPC39 MCC14 – MCC13
are both non-zero
MCC13 is non-zero and PPC39 must be within 00000 PPC39 MCC10 – MCC13
MCC14 is zero
MCC13 is zero and PPC39 must be within 00000 PPC39 MCC14 – MCC09
MCC14 is non-zero .
MCC13 and MCC14 PPC39 must be within 00000 PPC39 MCC10 – MCC09
are both zero
0442 PPC42 is out of range.
If non-zero, PPC42 must be within PLC41
PPC42 PLC42
0443 PPC43 is out of range.
if: then:
MCC13 and MCC14 PPC43 must be within 00000 PPC43 MCC14 – MCC13
are both non-zero
MCC13 is non-zero and PPC43 must be within 00000 PPC43 MCC10 – MCC13.
MCC14 is zero
MCC13 is zero and PPC43 must be within 00000 PPC43 MCC14 – MCC09.
MCC14 is non-zero
MCC13 and MCC14 PPC43 must be within 00000 PPC43 MCC10 – MCC09
are both zero
0446 PPC46 is out of range.
If non-zero, PPC46 must be within PLC41
PPC46 PLC42
0447 PPC47 is out of range.
if: then:
MCC13 and MCC14 PPC47 must be within 00000 PPC47 MCC14 – MCC13
are both non-zero
MCC13 is non-zero and PPC47 must be within 00000 PPC47 MCC10 – MCC13.
MCC14 is zero
MCC13 is zero and PPC47 must be within 00000 PPC47 MCC14 – MCC09.
MCC14 is non-zero
MCC13 and MCC14 PPC47 must be within 00000 PPC47 MCC10 – MCC09
are both zero
0450 PPC50 is out of range.
If non-zero, PPC50 must be within PLC41
PPC50 PLC42
0452
PPC52 is out of range. Valid range is 00000 PPC52 PLC42
0461 PPC61 is out of range.
if: then:
MCC13 and MCC14 PPC61 must be within 00000 PPC61 MCC14 – MCC13
are both non-zero
MCC13 is non-zero and PPC61 must be within 00000 PPC61 MCC10 – MCC13.
MCC14 is zero
MCC13 is zero and PPC61 must be within 00000 PPC61 MCC14 – MCC09
MCC14 is non-zero .
MCC13 and MCC14 PPC61 must be within 00000 PPC61 MCC10 – MCC09
are both zero