Manual
4–14 Programming Error Codes
Publication
1771-6.5.126 – March 1998
Error Code
Description
IPC ID = 9
0728 IPC28 cannot be 00000 when IPC30 > 00000.
0731 IPC31 cannot be 00000 because it conflicts with one of:0
731
I
P
C
31 cannot be
00000
becau
s
e it con
f
lict
s
w
ith one o
f
:
IPC33 > 00000 when IPC03-B01 = 0
P 33 hen P 3- 1 =
IPC34 > 00000 when IPC03-B01 = 1
0732 IPC32 cannot be 00000 when IPC34 > 00000.
0735 IPC35 cannot be 00000 because it conflicts with one of:
P 37 hen P 3- 1 =
I
P
C
37
>
00000
w
hen
I
P
C0
3-
B0
1 =
0
IPC38 > 00000 when IPC03-B01 = 1
0736 IPC36 cannot be 00000 when IPC38 > 00000.
0739 IPC39 cannot be 00000 because it conflicts with one of:
0
739
I
P
C
39 cannot be
00000
becau
s
e it con
f
lict
s
w
ith one o
f
:
IPC41 > 00000 when IPC03-B01 = 0
P 41 hen P 3- 1 =
IPC42 > 00000 when IPC03-B01 = 1
0740 IPC40 cannot be 00000 when IPC42 > 00000.
0743 IPC43 cannot be 00000 because it conflicts with one of:0
743
I
P
C
43 cannot be
00000
becau
s
e it con
f
lict
s
w
ith one o
f
:
IPC45 > 00000 when IPC03-B01 = 0
P 45 hen P 3- 1 =
IPC46 > 00000 when IPC03-B01 = 1
0744 IPC44 cannot be 00000 when IPC46 > 00000.
0747 IPC47 cannot be 00000 because it conflicts with one of:0
747
I
P
C
47 cannot be
00000
becau
s
e it con
f
lict
s
w
ith one o
f
:
IPC49 > 00000 when IPC03-B01 = 0
P 49 hen P 3- 1 =
IPC50 > 00000 when IPC03-B01 = 1
0748 IPC48 cannot be 00000 when IPC50 > 00000.
0757 You have selected Pressure Limited Vel/Pos execution for the Injection Profile by
IPC03-B01 = 0 and IPC03-B00 = 1. This mode of Injection Profile execution does not allow
a 00000 entry for IPC57.
0815 IPC15 must be 00000 when IPC11 = 00000.
0816 IPC16 must be 00000 when IPC12 = 00000.
0819 IPC19 must be 00000 when IPC15 = 00000.
0820 IPC20 must be 00000 when IPC16 = 00000.
0823 IPC23 must be 00000 when IPC19 = 00000.
0824 IPC24 must be 00000 when IPC20 = 00000.
0827 IPC27 must be 00000 when IPC23 = 00000.
0828 IPC28 must be 00000 when IPC24 = 00000.
0831 IPC31 must be 00000 when IPC27 = 00000.
0832 IPC32 must be 00000 when IPC28 = 00000.
0835 IPC35 must be 00000 when IPC31 = 00000.
0836 IPC36 must be 00000 when IPC32 = 00000.
0839 IPC39 must be 00000 when IPC35 = 00000.
0840 IPC40 must be 00000 when IPC36 = 00000.
0843 IPC43 must be 00000 when IPC39 = 00000.
0844 IPC44 must be 00000 when IPC40 = 00000.
0847 IPC47 must be 00000 when IPC43 = 00000.
0848 IPC48 must be 00000 when IPC44 = 00000.
0862 IPC62 must be zero because your bit patterns in MCC02 and MCC03 indicate that the QI
module does not have access to a connected ram (screw) pressure transducer.
0863 IPC63 must be zero because your bit patterns in MCC02 and MCC03 indicate that the QI
module has no access to a connected cavity pressure transducer.
0960 Your entry combination as follows is illegal: IPC60 = IPC61 = IPC62 = IPC63 = 00000
1015 IPC15 is not in decreasing positional order
.
If non-zero, IPC15 must be less than IPC11.
1019 IPC19 is not in decreasing positional order.
If non-zero, IPC19 must be less than IPC15.