Manual

4–12 Programming Error Codes
Publication
1771-6.5.126 – March 1998
Error Code
Description IPC ID = 9
0441 IPC41 is out of range.
When IPC03-B14 = 1, a non-zero IPC41 must be within INC45
IPC41 INC46
0442 IPC42 is out of range.
If non-zero, IPC42 must be within INC41
IPC42 INC42
0443 IPC43 is out of range.
if: then:
MCC13 and MCC14 IPC43 must be within 00000 IPC43 MCC14 – MCC13
are both non-zero
MCC13 is non-zero and IPC43 must be within 00000 IPC43 MCC10 – MCC13.
MCC14 is zero
MCC13 is zero and IPC43 must be within 00000 IPC43 MCC14 – MCC09.
MCC14 is non-zero
MCC13 and MCC14 IPC43 must be within 00000 IPC43 MCC10 – MCC09
are both zero
0445 IPC45 is out of range.
When IPC03-B14 = 1, a non-zero IPC45 must be within INC45
IPC45 INC46
0446 IPC46 is out of range.
If non-zero, IPC46 must be within INC41
IPC46 INC42
0447 IPC47 is out of range.
if: then:
MCC13 and MCC14 IPC47 must be within 00000 IPC47 MCC14 – MCC13
are both non-zero
MCC13 is non-zero and IPC47 must be within 00000 IPC47 MCC10 – MCC13.
MCC14 is zero
MCC13 is zero and IPC47 must be within 00000 IPC47 MCC14 – MCC09.
MCC14 is non-zero
MCC13 and MCC14 IPC47 must be within 00000 IPC47 MCC10 – MCC09
are both zero
0449 IPC49 is out of range.
When IPC03-B14 = 1, a non-zero IPC49 must be within INC45
IPC49 INC46
0450 IPC50 is out of range.
If non-zero, IPC50 must be within INC41
IPC50 INC42
0451 IPC51 is out of range.
When IPC03-B14 = 1, IPC51 must be within 00000
IPC51 INC46
0452
IPC52 is out of range. Valid range is 00000 IPC52 INC42
0454
IPC54 is out of range. Valid range is INC45 IPC54 INC46
0455
IPC55 is out of range. Valid range is INC41 IPC55 INC42
0456 IPC56 is out of range. Valid range must be compatible with min/max ram (screw) position
limits (MCC09/MCC10) and min/max software travel limits (MCC13/MCC14)
0457 You have selected Pressure Limited Vel/Pos execution for the Injection Profile by
P 3- 1 = and P 3- = 1 ho ever P 57 i out o ran e.
I
P
C0
3-
B0
1 =
0
and
I
P
C0
3-
B00
= 1
;
ho
w
ever
,
I
P
C
57 i
s
out o
f
ran
g
e.
IPC57 must be within MCC17 < IPC57 MCC18
0458 You have selected Pressure Limited Vel/Pos execution for the Injection Profile by
IPC03-B01 = 0 and IPC03-B00 = 1.
IPC58 is out of range.
if: then:
MCC13 and MCC14 IPC58 must be within 00000 IPC58 MCC14 – MCC13
are both non-zero
MCC13 is non-zero and IPC58 must be within 00000 IPC58 MCC10 – MCC13.
MCC14 is zero
MCC13 is zero and IPC58 must be within 00000 IPC58 MCC14 – MCC09.
MCC14 is non-zero
MCC13 and MCC14 IPC58 must be within 00000 IPC58 MCC10 – MCC09
are both zero