4–2 Programming Error Codes
Publication
1771-6.5.126 – March 1998
Type Example Description
2
222
Outside fixed limits
0
2
0
222
MCC22 is out of range. Valid range is 00000 MCC22 00099.
3
Cannot be equal
0
3
0311
MCC11 is equal to MCC12. They must not be equal.
Outside range established by another entry
04
0427
MCC27 is out of range.
If MCC28 is non-zero, MCC27 must be within
MCC23
MCC27 MCC28.
If MCC28 is zero, MCC27 must be within
MCC23
MCC27 MCC24.
5
52
Bit selection error
0
5
0
5
0
2
MCC02-B04=1 and/or MCC02-B05=1 are illegal configurations.
Block-related configuration error
06 0600
Your entire IPC block has been rejected because the QI module
does not have a valid MCC block on-board (SYS15-B07 = 0)
7
712
Required non-zero entry
0
7
0
712
IPC12 cannot be zero when IPC14 > 00000.
8
816
Entry must be zero
0
8
0
816
IPC16 must be 00000 when IPC12 = 00000.
Entry combination error (group is outside fixed limits)
09 0960
Your entry combination is illegal:
IPC60 = IPC61 = IPC62 = IPC63 = 00000.
Error in entry order
10
1015
IPC is not in decreasing positional order.
If non-zero, IPC15 must be less than IPC11.