Manual

Chapter 4
Publication
1771-6.5.126 – March 1998
Programming Error Codes
Programming error codes indicate that you entered invalid data in a
command block. This chapter lists programming error codes for all
command blocks.
Block
ID:
Acronym: Description: Page:
1 MCC Module Configuration Command Block 4-3
2 JGC Jog Configuration Block 4-6
8 INC Injection Configuration Block 4-7
9 IPC Injection Profile Block 4-9
10 PKC Pack Configuration Block 4-15
11 HDC Hold Configuration Block 4-16
12 HPC Pack/Hold Profile Block 4-17
13 PRC Pre-Decompression Configuration Block 4-20
14 PLC Plastication Configuration Block 4-21
15 PPC Plastication Profile Block 4-22
16 PSC Post-Decompression Configuration Block 4-28
25 DYC Dynamic Command Block 4-29
26 RLC Inject ERC Values Block 4-29
28 PTC Process Trace Configuration Block 4-30
Important: Refer to the block ID returned in SYS61 to determine
the command block to which the error code relates. Then refer to
SYS62 for the error code.
You read error codes on your programming terminal by examining
system status words in the PLC data table:
SYS61 = ID of the block that contains the error
SYS62 = error code
You can interpret most error codes by memorizing 9 basic types and
knowing how the codes are organized.
The 4-digit code, xxyy, has two parts:
xx = type description
yy = word in the command block that contains the error
Here we list the type descriptions, each with an example error code.
How to Read Error Codes