User Manual
Table Of Contents
- 1771-6.5.88, Plastic Molding Module Reference Manual
- Summary of Changes
- Table of Contents
- Preface
- 1 - Abbreviated Command and Status Blocks
- Chapter Contents
- CLC - Clamp and Eject ERC Values Block
- CPC - Clamp Close Profile Block
- DYC - Dynamic Command Block
- EAC - Ejector Advance Configuration Block
- EPC - Ejector Profile Block
- ERC - Ejector Retract Configuration Block
- FCC - First Clamp Close Configuration Block
- FOC - First Clamp Open Configuration Block
- HDC - Hold Configuration Block
- HPC - Pack/Hold Profile Block
- INC - Injection Configuration Block
- IPC - Injection Profile Block
- JGC - Jog Configuration Block
- LPC - Clamp Low Pressure Close Configuration Block
- MCC - Module Configuration Command Block
- OPC - Clamp Open Profile Block
- OSC - Clamp Open Slow Configuration Block
- PKC - Pack Configuration Block
- PLC - Plastication Configuration Block
- PPC - Plastication Profile Block
- PRC - Pre-decompression Configuration Block
- PSC - Post- decompression Configuration Block
- PTC - Process Trace Configuration Block
- RLC - Inject ERC Values Block
- SCC - Second Clamp Close Configuration Block
- SOC - Second Clamp Open Configuration Block
- TCC - Third Clamp Close Configuration Block
- TOC - Third Clamp Open Configuration Block
- CLS - Clamp and Eject ERC Values Status Block
- CPS - Clamp Close Profiles Status Block
- EPS - Ejector Profile Status Block
- HPS - Pack/Hold Profile Status Block
- IPS - Injection Profile Status Block
- OPS - Clamp Open Profiles Status Block
- PPS - Plastication Profile Status Block
- PTS - Process Trace Status Block
- RLS - Inject ERC Values Status Block
- SYS - System Status Block
- 2 - Command Word/Bit Descriptions
- Alphabetical List of Command Blocks and Block ID Codes
- List of Data Words
- Engineering Units
- Data Blocks Require I/O Configuration
- Data Blocks for System Control
- Data Blocks for Controlling Ram (Screw) Position
- Data Blocks for Controlling Clamp Position
- Data Blocks for Controlling Ejector Position
- Sensors Required
- CLC CLC - Clamp and Eject ERC Values Block
- CPC - Clamp Close Profile Block
- DYC DYC - Dynamic Command Block
- EAC - Ejector Advance Configuration Block
- EPC - Ejector Profile Block
- ERC - Ejector Retract Configuration Block
- FCC - First Clamp Close Configuration Block
- FOC - First Clamp Open Configuration Block
- HDC - Hold Configuration Block
- HPC - Pack/Hold Profile Block
- INC - Injection Configuration Block
- IPC - Injection Profile Block
- JGC - Jog Configuration Block
- LPC - Clamp Low Pressure Close Configuration Block
- MCC - Module Configuration Command Block
- OPC - Clamp Open Profile Block
- OSC - Clamp Open Slow Configuration Block
- PKC - Pack Configuration Block
- PLC Plastication Configuration Command Block (PLC)
- PPC - Plastication Profile Block
- PRC - Pre-decompression Configuration Block
- PSC - Post-decompression Configuration Block
- PTC - Process Trace Configuration Block
- RLC - Inject ERC Values Block
- SCC - Second Clamp Close Configuration Block
- SOC - Second Clamp Open Configuration Block
- TCC - Third Clamp Close Configuration Block
- TOC - Third Clamp Open Configuration Block
- 3 - Word/Bit Descriptions
- List of Status Blocks and Block ID Codes
- List of Data Words
- Data Blocks Require I/O Configuration
- Engineering Units
- Status Block for Reporting System Status
- Status Blocks for Reporting Ram (Screw) Position
- Status Blocks for Reporting Clamp Position
- Status Blocks for Reporting Ejector Position
- CLS - Clamp and Eject ERC Values Status Block
- CPS - Clamp Close Profiles Status Block
- EPS - Ejector Profile Status Block
- HPS - Pack/Hold Profile Status Block
- IPS ú Injection Profile Status Block
- OPS - Clamp Open Profiles Status Block
- PPS - Plastication Profile Status Block
- PTS - Process Trace Status Block
- RLS - Inject ERC Values Status Block
- SYS - System Status Block
- 4 - Programming Error Codes
- 5 - Module Specifications
- 6 - Calibration Instructions
- A - Single transfer for Reporting Ejector Status
- Back cover

2–19Command Word/Bit Descriptions
Publication
1771-6.5.88 – July 1997
DYC
Word Bit Description
DYC02 B10 If clamp position is less than OPC61 and
all within each group
are true:
then the module:
– OPC11 is not zero
– clamp position less than non-zero entry in OPC11, OPC14, or OPC17
terminates any action in progress (except ongoing
Ejector Profile) and starts First Clamp Open Profile
– OPC11 is zero or is not zero when clamp position exceeds all
non-zero entries in OPC11, OPC14, and OPC17
–OPC03-B08 is SET
terminates any action in progress (except ongoing
Ejector Profile) and sets outputs to FOC33 - FOC40
– OPC11 is zero or is not zero when clamp position exceeds all
non-zero entries in OPC11, OPC14, and OPC17
– OPC03-B08 is RESET
– OPC20 is not zero
– clamp position less than non-zero entry in OPC20, OPC23, or OPC26
terminates any action in progress (except ongoing
Ejector Profile) and starts Second Clamp Open
Profile
– OPC11 is zero or is not zero when clamp position exceeds all
non-zero entries in OPC11,OPC14, and OPC17
– OPC03-B08 is RESET
– OPC20 is zero or is not zero when clamp position exceeds all
non-zero entries in OPC20, OPC23, and OPC26
– OPC03-B09 is SET
terminates any action in progress (except ongoing
Ejector Profile) and sets outputs to SOC33 - SOC40
– OPC11 is zero or is not zero when clamp position exceeds all
non-zero entries in OPC11, OPC14, and OPC17
– OPC03-B08 is RESET
– OPC20 is zero or is not zero when clamp position exceeds all
non-zero entries in OPC20, OPC23, and OPC26
– OPC03-B09 is RESET
– OPC29 is not zero
– clamp position exceeds non-zero entry in OPC29, OPC32, or OPC35
terminates any action in progress (except ongoing
Ejector Profile) and starts Third Clamp Open Profile
– OPC11 is zero or is not zero when clamp position exceeds all
non-zero entries in OPC11,OPC14, and OPC17
– OPC03-B08 is RESET
– OPC20 is zero or is not zero when clamp position exceeds all
non-zero entries in OPC20, OPC23, and OPC26
– OPC03-B09 is RESET
– OPC29 is zero or is not zero when clamp position exceeds all
non-zero entries in OPC29, OPC32, and OPC35
– OPC03-B10 is SET
terminates any action in progress (except ongoing
Ejector Profile) and sets outputs to TOC33 - TOC40
– OPC11 is zero or is not zero when clamp position exceeds all
non-zero entries in OPC11, OPC14, and OPC17
– OPC03-B08 is RESET
– OPC20 is zero or is not zero when clamp position exceeds all
non-zero entries in OPC20, OPC23, and OPC26
– OPC03-B09 is RESET
– OPC29 is zero or is not zero when clamp position exceeds all
non-zero entries in OPC29, OPC32, and OPC35
– OPC03-B10 is RESET
Also occurs for clamp position less than OPC62 but not less than OPC61.
terminates any action in progress (except ongoing
Ejector Profile) and starts Clamp Open Slow Profile
clamp position equals or exceeds OPC62
terminates any action in progress (except ongoing
Ejector Profile) and sets outputs to OSC33 - OSC40