User Manual
Table Of Contents
- 1771-6.5.88, Plastic Molding Module Reference Manual
- Summary of Changes
- Table of Contents
- Preface
- 1 - Abbreviated Command and Status Blocks
- Chapter Contents
- CLC - Clamp and Eject ERC Values Block
- CPC - Clamp Close Profile Block
- DYC - Dynamic Command Block
- EAC - Ejector Advance Configuration Block
- EPC - Ejector Profile Block
- ERC - Ejector Retract Configuration Block
- FCC - First Clamp Close Configuration Block
- FOC - First Clamp Open Configuration Block
- HDC - Hold Configuration Block
- HPC - Pack/Hold Profile Block
- INC - Injection Configuration Block
- IPC - Injection Profile Block
- JGC - Jog Configuration Block
- LPC - Clamp Low Pressure Close Configuration Block
- MCC - Module Configuration Command Block
- OPC - Clamp Open Profile Block
- OSC - Clamp Open Slow Configuration Block
- PKC - Pack Configuration Block
- PLC - Plastication Configuration Block
- PPC - Plastication Profile Block
- PRC - Pre-decompression Configuration Block
- PSC - Post- decompression Configuration Block
- PTC - Process Trace Configuration Block
- RLC - Inject ERC Values Block
- SCC - Second Clamp Close Configuration Block
- SOC - Second Clamp Open Configuration Block
- TCC - Third Clamp Close Configuration Block
- TOC - Third Clamp Open Configuration Block
- CLS - Clamp and Eject ERC Values Status Block
- CPS - Clamp Close Profiles Status Block
- EPS - Ejector Profile Status Block
- HPS - Pack/Hold Profile Status Block
- IPS - Injection Profile Status Block
- OPS - Clamp Open Profiles Status Block
- PPS - Plastication Profile Status Block
- PTS - Process Trace Status Block
- RLS - Inject ERC Values Status Block
- SYS - System Status Block
- 2 - Command Word/Bit Descriptions
- Alphabetical List of Command Blocks and Block ID Codes
- List of Data Words
- Engineering Units
- Data Blocks Require I/O Configuration
- Data Blocks for System Control
- Data Blocks for Controlling Ram (Screw) Position
- Data Blocks for Controlling Clamp Position
- Data Blocks for Controlling Ejector Position
- Sensors Required
- CLC CLC - Clamp and Eject ERC Values Block
- CPC - Clamp Close Profile Block
- DYC DYC - Dynamic Command Block
- EAC - Ejector Advance Configuration Block
- EPC - Ejector Profile Block
- ERC - Ejector Retract Configuration Block
- FCC - First Clamp Close Configuration Block
- FOC - First Clamp Open Configuration Block
- HDC - Hold Configuration Block
- HPC - Pack/Hold Profile Block
- INC - Injection Configuration Block
- IPC - Injection Profile Block
- JGC - Jog Configuration Block
- LPC - Clamp Low Pressure Close Configuration Block
- MCC - Module Configuration Command Block
- OPC - Clamp Open Profile Block
- OSC - Clamp Open Slow Configuration Block
- PKC - Pack Configuration Block
- PLC Plastication Configuration Command Block (PLC)
- PPC - Plastication Profile Block
- PRC - Pre-decompression Configuration Block
- PSC - Post-decompression Configuration Block
- PTC - Process Trace Configuration Block
- RLC - Inject ERC Values Block
- SCC - Second Clamp Close Configuration Block
- SOC - Second Clamp Open Configuration Block
- TCC - Third Clamp Close Configuration Block
- TOC - Third Clamp Open Configuration Block
- 3 - Word/Bit Descriptions
- List of Status Blocks and Block ID Codes
- List of Data Words
- Data Blocks Require I/O Configuration
- Engineering Units
- Status Block for Reporting System Status
- Status Blocks for Reporting Ram (Screw) Position
- Status Blocks for Reporting Clamp Position
- Status Blocks for Reporting Ejector Position
- CLS - Clamp and Eject ERC Values Status Block
- CPS - Clamp Close Profiles Status Block
- EPS - Ejector Profile Status Block
- HPS - Pack/Hold Profile Status Block
- IPS ú Injection Profile Status Block
- OPS - Clamp Open Profiles Status Block
- PPS - Plastication Profile Status Block
- PTS - Process Trace Status Block
- RLS - Inject ERC Values Status Block
- SYS - System Status Block
- 4 - Programming Error Codes
- 5 - Module Specifications
- 6 - Calibration Instructions
- A - Single transfer for Reporting Ejector Status
- Back cover

1–43Abbreviated Command and Status Blocks
Publication
1771-6.5.88 – July 1997
Actuals from 1st Clamp Open Profile
OPS09
N43:717 Segment 1 velocity
OPS10 N43:718 Segment 1 pressure
OPS11 N43:719 Segment 1 execution time
OPS12 N43:720 Segment 2 velocity
OPS13 N43:721 Segment 2 pressure
OPS14 N43:722 Segment 2 execution time
OPS15 N43:723 Segment 3 velocity
OPS16 N43:724 Segment 3 pressure
OPS17 N43:725 Segment 3 execution time
Actuals from 2nd Clamp Open Profile
OPS18 N43:726 Segment 4 velocity
OPS19 N43:727 Segment 4 pressure
OPS20 N43:728 Segment 4 execution time
OPS21 N43:729 Segment 5 velocity
OPS22 N43:730 Segment 5 pressure
OPS23 N43:731 Segment 5 execution time
OPS24 N43:732 Segment 6 velocity
OPS25 N43:733 Segment 6 pressure
OPS26 N43:734 Segment 6 execution time
Actuals from 3rd Clamp Open Profile
OPS27 N43:735 Segment 7 velocity
OPS28 N43:736 Segment 7 pressure
OPS29 N43:737 Segment 7 execution time
OPS30 N43:738 Segment 8 velocity
OPS31 N43:739 Segment 8 pressure
OPS32 N43:740 Segment 8 execution time
OPS33 N43:741 Segment 9 velocity
OPS34 N43:742 Segment 9 pressure
OPS35 N43:743 Segment 9 execution time
Actuals from Clamp Open Slow Profile
OPS36 N43:744 Segment 1 velocity
OPS37 N43:745 Segment 1 pressure
OPS38 N43:746 Segment 1 execution time
OPS39 N43:747 Segment 2 velocity
OPS40 N43:748 Segment 2 pressure
OPS41 N43:749 Segment 2 execution time
OPS42 N43:750 Starting velocity
OPS43 N43:751 Starting pressure
OPS44 N43:752 Starting position
OPS45 N43:753 Ending velocity
OPS46 N43:754 Ending pressure
OPS47 N43:755 Ending position
OPS48-52 N43:756-760 RFU
Maximum Pressures During Clamp Open Profiles
OPS53 N43:761 During first profile
OPS54 N43:762 During second profile
OPS55 N43:763 During third profile
OPS56 N43:764 During open slow profile