User Manual
Table Of Contents
- 1771-6.5.88, Plastic Molding Module Reference Manual
- Summary of Changes
- Table of Contents
- Preface
- 1 - Abbreviated Command and Status Blocks
- Chapter Contents
- CLC - Clamp and Eject ERC Values Block
- CPC - Clamp Close Profile Block
- DYC - Dynamic Command Block
- EAC - Ejector Advance Configuration Block
- EPC - Ejector Profile Block
- ERC - Ejector Retract Configuration Block
- FCC - First Clamp Close Configuration Block
- FOC - First Clamp Open Configuration Block
- HDC - Hold Configuration Block
- HPC - Pack/Hold Profile Block
- INC - Injection Configuration Block
- IPC - Injection Profile Block
- JGC - Jog Configuration Block
- LPC - Clamp Low Pressure Close Configuration Block
- MCC - Module Configuration Command Block
- OPC - Clamp Open Profile Block
- OSC - Clamp Open Slow Configuration Block
- PKC - Pack Configuration Block
- PLC - Plastication Configuration Block
- PPC - Plastication Profile Block
- PRC - Pre-decompression Configuration Block
- PSC - Post- decompression Configuration Block
- PTC - Process Trace Configuration Block
- RLC - Inject ERC Values Block
- SCC - Second Clamp Close Configuration Block
- SOC - Second Clamp Open Configuration Block
- TCC - Third Clamp Close Configuration Block
- TOC - Third Clamp Open Configuration Block
- CLS - Clamp and Eject ERC Values Status Block
- CPS - Clamp Close Profiles Status Block
- EPS - Ejector Profile Status Block
- HPS - Pack/Hold Profile Status Block
- IPS - Injection Profile Status Block
- OPS - Clamp Open Profiles Status Block
- PPS - Plastication Profile Status Block
- PTS - Process Trace Status Block
- RLS - Inject ERC Values Status Block
- SYS - System Status Block
- 2 - Command Word/Bit Descriptions
- Alphabetical List of Command Blocks and Block ID Codes
- List of Data Words
- Engineering Units
- Data Blocks Require I/O Configuration
- Data Blocks for System Control
- Data Blocks for Controlling Ram (Screw) Position
- Data Blocks for Controlling Clamp Position
- Data Blocks for Controlling Ejector Position
- Sensors Required
- CLC CLC - Clamp and Eject ERC Values Block
- CPC - Clamp Close Profile Block
- DYC DYC - Dynamic Command Block
- EAC - Ejector Advance Configuration Block
- EPC - Ejector Profile Block
- ERC - Ejector Retract Configuration Block
- FCC - First Clamp Close Configuration Block
- FOC - First Clamp Open Configuration Block
- HDC - Hold Configuration Block
- HPC - Pack/Hold Profile Block
- INC - Injection Configuration Block
- IPC - Injection Profile Block
- JGC - Jog Configuration Block
- LPC - Clamp Low Pressure Close Configuration Block
- MCC - Module Configuration Command Block
- OPC - Clamp Open Profile Block
- OSC - Clamp Open Slow Configuration Block
- PKC - Pack Configuration Block
- PLC Plastication Configuration Command Block (PLC)
- PPC - Plastication Profile Block
- PRC - Pre-decompression Configuration Block
- PSC - Post-decompression Configuration Block
- PTC - Process Trace Configuration Block
- RLC - Inject ERC Values Block
- SCC - Second Clamp Close Configuration Block
- SOC - Second Clamp Open Configuration Block
- TCC - Third Clamp Close Configuration Block
- TOC - Third Clamp Open Configuration Block
- 3 - Word/Bit Descriptions
- List of Status Blocks and Block ID Codes
- List of Data Words
- Data Blocks Require I/O Configuration
- Engineering Units
- Status Block for Reporting System Status
- Status Blocks for Reporting Ram (Screw) Position
- Status Blocks for Reporting Clamp Position
- Status Blocks for Reporting Ejector Position
- CLS - Clamp and Eject ERC Values Status Block
- CPS - Clamp Close Profiles Status Block
- EPS - Ejector Profile Status Block
- HPS - Pack/Hold Profile Status Block
- IPS ú Injection Profile Status Block
- OPS - Clamp Open Profiles Status Block
- PPS - Plastication Profile Status Block
- PTS - Process Trace Status Block
- RLS - Inject ERC Values Status Block
- SYS - System Status Block
- 4 - Programming Error Codes
- 5 - Module Specifications
- 6 - Calibration Instructions
- A - Single transfer for Reporting Ejector Status
- Back cover

1–17Abbreviated Command and Status Blocks
Publication
1771-6.5.88 – July 1997
Screw-rotate-jog Set-output Values
JGC09
N40:65 Output #1
JGC10 N40:66 Output #2
JGC11 N40:67 Output #3
JGC12 N40:68 Output #4
JGC13 N40:69 Output #5
JGC14 N40:70 Output #6
JGC15 N40:71 Output #7
JGC16 N40:72 Output #8
Ram(Screw)-forward-jog Set-output Values
JGC17 N40:73 Output #1
JGC18 N40:74 Output #2
JGC19 N40:75 Output #3
JGC20 N40:76 Output #4
JGC21 N40:77 Output #5
JGC22 N40:78 Output #6
JGC23 N40:79 Output #7
JGC24 N40:80 Output #8
Ram(Screw)-reverse-jog Set-output Values
JGC25 N40:81 Output #1
JGC26 N40:82 Output #2
JGC27 N40:83 Output #3
JGC28 N40:84 Output #4
JGC29 N40:85 Output #5
JGC30 N40:86 Output #6
JGC31 N40:87 Output #7
JGC32 N40:88 Output #8
Clamp-forward-jog Set-output Values
JGC33 N40:89 Output #1
JGC34 N40:90 Output #2
JGC35 N40:91 Output #3
JGC36 N40:92 Output #4
JGC37 N40:93 Output #5
JGC38 N40:94 Output #6
JGC39 N40:95 Output #7
JGC40 N40:96 Output #8
Clamp-reverse-jog Set-output Values
JGC41 N40:97 Output #1
JGC42 N40:98 Output #2
JGC43 N40:99 Output #3
JGC44 N40:100 Output #4
JGC45 N40:101 Output #5
JGC46 N40:102 Output #6
JGC47 N40:103 Output #7
JGC48 N40:104 Output #8
Ejector-advance-jog Set-output Values
JGC49 N40:105 Output #1
JGC50 N40:106 Output #2
JGC51 N40:107 Output #3
JGC52 N40:108 Output #4