User Manual
Table Of Contents
- 1771-6.5.88, Plastic Molding Module Reference Manual
- Summary of Changes
- Table of Contents
- Preface
- 1 - Abbreviated Command and Status Blocks
- Chapter Contents
- CLC - Clamp and Eject ERC Values Block
- CPC - Clamp Close Profile Block
- DYC - Dynamic Command Block
- EAC - Ejector Advance Configuration Block
- EPC - Ejector Profile Block
- ERC - Ejector Retract Configuration Block
- FCC - First Clamp Close Configuration Block
- FOC - First Clamp Open Configuration Block
- HDC - Hold Configuration Block
- HPC - Pack/Hold Profile Block
- INC - Injection Configuration Block
- IPC - Injection Profile Block
- JGC - Jog Configuration Block
- LPC - Clamp Low Pressure Close Configuration Block
- MCC - Module Configuration Command Block
- OPC - Clamp Open Profile Block
- OSC - Clamp Open Slow Configuration Block
- PKC - Pack Configuration Block
- PLC - Plastication Configuration Block
- PPC - Plastication Profile Block
- PRC - Pre-decompression Configuration Block
- PSC - Post- decompression Configuration Block
- PTC - Process Trace Configuration Block
- RLC - Inject ERC Values Block
- SCC - Second Clamp Close Configuration Block
- SOC - Second Clamp Open Configuration Block
- TCC - Third Clamp Close Configuration Block
- TOC - Third Clamp Open Configuration Block
- CLS - Clamp and Eject ERC Values Status Block
- CPS - Clamp Close Profiles Status Block
- EPS - Ejector Profile Status Block
- HPS - Pack/Hold Profile Status Block
- IPS - Injection Profile Status Block
- OPS - Clamp Open Profiles Status Block
- PPS - Plastication Profile Status Block
- PTS - Process Trace Status Block
- RLS - Inject ERC Values Status Block
- SYS - System Status Block
- 2 - Command Word/Bit Descriptions
- Alphabetical List of Command Blocks and Block ID Codes
- List of Data Words
- Engineering Units
- Data Blocks Require I/O Configuration
- Data Blocks for System Control
- Data Blocks for Controlling Ram (Screw) Position
- Data Blocks for Controlling Clamp Position
- Data Blocks for Controlling Ejector Position
- Sensors Required
- CLC CLC - Clamp and Eject ERC Values Block
- CPC - Clamp Close Profile Block
- DYC DYC - Dynamic Command Block
- EAC - Ejector Advance Configuration Block
- EPC - Ejector Profile Block
- ERC - Ejector Retract Configuration Block
- FCC - First Clamp Close Configuration Block
- FOC - First Clamp Open Configuration Block
- HDC - Hold Configuration Block
- HPC - Pack/Hold Profile Block
- INC - Injection Configuration Block
- IPC - Injection Profile Block
- JGC - Jog Configuration Block
- LPC - Clamp Low Pressure Close Configuration Block
- MCC - Module Configuration Command Block
- OPC - Clamp Open Profile Block
- OSC - Clamp Open Slow Configuration Block
- PKC - Pack Configuration Block
- PLC Plastication Configuration Command Block (PLC)
- PPC - Plastication Profile Block
- PRC - Pre-decompression Configuration Block
- PSC - Post-decompression Configuration Block
- PTC - Process Trace Configuration Block
- RLC - Inject ERC Values Block
- SCC - Second Clamp Close Configuration Block
- SOC - Second Clamp Open Configuration Block
- TCC - Third Clamp Close Configuration Block
- TOC - Third Clamp Open Configuration Block
- 3 - Word/Bit Descriptions
- List of Status Blocks and Block ID Codes
- List of Data Words
- Data Blocks Require I/O Configuration
- Engineering Units
- Status Block for Reporting System Status
- Status Blocks for Reporting Ram (Screw) Position
- Status Blocks for Reporting Clamp Position
- Status Blocks for Reporting Ejector Position
- CLS - Clamp and Eject ERC Values Status Block
- CPS - Clamp Close Profiles Status Block
- EPS - Ejector Profile Status Block
- HPS - Pack/Hold Profile Status Block
- IPS ú Injection Profile Status Block
- OPS - Clamp Open Profiles Status Block
- PPS - Plastication Profile Status Block
- PTS - Process Trace Status Block
- RLS - Inject ERC Values Status Block
- SYS - System Status Block
- 4 - Programming Error Codes
- 5 - Module Specifications
- 6 - Calibration Instructions
- A - Single transfer for Reporting Ejector Status
- Back cover

4–50 Programming Error Codes
Publication
1771-6.5.88 – July 1997
Error Code
Description
ID = 21
0218
CLC18 is out of range. Valid range is 00000
≤
CLC18
≤
09999
0219
CLC19 is out of range. Valid range is 00000
≤
CLC19
≤
09999
0220
CLC20 is out of range. Valid range is 00000
≤
CLC20
≤
09999
0221
CLC21 is out of range. Valid range is 00000
≤
CLC21
≤
09999
0222
CLC22 is out of range. Valid range is 00000
≤
CLC22
≤
09999
0223
CLC23 is out of range. Valid range is 00000
≤
CLC23
≤
09999
0224
CLC24 is out of range. Valid range is 00000
≤
CLC24
≤
09999
ID = 22
EAC – Ejector Advance Configuration Block
Error Code
Description
ID = 22
0205
EAC05 is out of range. Valid range is 00000
≤
EAC05
≤
09999
0206
EAC06 is out of range. Valid range is 00000
≤
EAC06
≤
09999
0208
EAC08 is out of range. Valid range is 00000
≤
EAC08
≤
09999
0209
EAC09 is out of range. Valid range is 00000
≤
EAC09
≤
09999
0210
EAC10 is out of range. Valid range is 00000
≤
EAC10
≤
09999
0211
EAC11 is out of range. Valid range is 00000
≤
EAC11
≤
09999
0212
EAC12 is out of range. Valid range is 00000
≤
EAC12
≤
09999
0213
EAC13 is out of range. Valid range is 00000
≤
EAC13
≤
09999
0214
EAC14 is out of range. Valid range is 00000
≤
EAC14
≤
09999
0215
EAC15 is out of range. Valid range is 00000
≤
EAC15
≤
09999
0216
EAC16 is out of range. Valid range is 00000
≤
EAC16
≤
09999
0217
EAC17 is out of range. Valid range is 00000
≤
EAC17
≤
09999
0218
EAC18 is out of range. Valid range is 00000
≤
EAC18
≤
09999
0219
EAC19 is out of range. Valid range is 00000
≤
EAC19
≤
09999
0220
EAC20 is out of range. Valid range is 00000
≤
EAC20
≤
09999
0221
EAC21 is out of range. Valid range is 00000
≤
EAC21
≤
09999
0222
EAC22 is out of range. Valid range is 00000
≤
EAC22
≤
09999
0223
EAC23 is out of range. Valid range is 00000
≤
EAC23
≤
09999
0224
EAC24 is out of range. Valid range is 00000
≤
EAC24
≤
09999
0225
EAC25 is out of range. Valid range is 00000
≤
EAC25
≤
09999
0226
EAC26 is out of range. Valid range is 00000
≤
EAC26
≤
09999
0227
EAC27 is out of range. Valid range is 00000
≤
EAC27
≤
09999
0228
EAC28 is out of range. Valid range is 00000
≤
EAC28
≤
09999
0229
EAC29 is out of range. Valid range is 00000
≤
EAC29
≤
09999
0230
EAC30 is out of range. Valid range is 00000
≤
EAC30
≤
09999
0231
EAC31 is out of range. Valid range is 00000
≤
EAC31
≤
09999
0232
EAC32 is out of range. Valid range is 00000
≤
EAC32
≤
09999
0233
EAC33 is out of range. Valid range is 00000
≤
EAC33
≤
09999
0234
EAC34 is out of range. Valid range is 00000
≤
EAC34
≤
09999
0235
EAC35 is out of range. Valid range is 00000
≤
EAC35
≤
09999
0236
EAC36 is out of range. Valid range is 00000
≤
EAC36
≤
09999
0237
EAC37 is out of range. Valid range is 00000
≤
EAC37
≤
09999
0238
EAC38 is out of range. Valid range is 00000
≤
EAC38
≤
09999
0239
EAC39 is out of range. Valid range is 00000
≤
EAC39
≤
09999