User Manual
Table Of Contents
- 1771-6.5.88, Plastic Molding Module Reference Manual
- Summary of Changes
- Table of Contents
- Preface
- 1 - Abbreviated Command and Status Blocks
- Chapter Contents
- CLC - Clamp and Eject ERC Values Block
- CPC - Clamp Close Profile Block
- DYC - Dynamic Command Block
- EAC - Ejector Advance Configuration Block
- EPC - Ejector Profile Block
- ERC - Ejector Retract Configuration Block
- FCC - First Clamp Close Configuration Block
- FOC - First Clamp Open Configuration Block
- HDC - Hold Configuration Block
- HPC - Pack/Hold Profile Block
- INC - Injection Configuration Block
- IPC - Injection Profile Block
- JGC - Jog Configuration Block
- LPC - Clamp Low Pressure Close Configuration Block
- MCC - Module Configuration Command Block
- OPC - Clamp Open Profile Block
- OSC - Clamp Open Slow Configuration Block
- PKC - Pack Configuration Block
- PLC - Plastication Configuration Block
- PPC - Plastication Profile Block
- PRC - Pre-decompression Configuration Block
- PSC - Post- decompression Configuration Block
- PTC - Process Trace Configuration Block
- RLC - Inject ERC Values Block
- SCC - Second Clamp Close Configuration Block
- SOC - Second Clamp Open Configuration Block
- TCC - Third Clamp Close Configuration Block
- TOC - Third Clamp Open Configuration Block
- CLS - Clamp and Eject ERC Values Status Block
- CPS - Clamp Close Profiles Status Block
- EPS - Ejector Profile Status Block
- HPS - Pack/Hold Profile Status Block
- IPS - Injection Profile Status Block
- OPS - Clamp Open Profiles Status Block
- PPS - Plastication Profile Status Block
- PTS - Process Trace Status Block
- RLS - Inject ERC Values Status Block
- SYS - System Status Block
- 2 - Command Word/Bit Descriptions
- Alphabetical List of Command Blocks and Block ID Codes
- List of Data Words
- Engineering Units
- Data Blocks Require I/O Configuration
- Data Blocks for System Control
- Data Blocks for Controlling Ram (Screw) Position
- Data Blocks for Controlling Clamp Position
- Data Blocks for Controlling Ejector Position
- Sensors Required
- CLC CLC - Clamp and Eject ERC Values Block
- CPC - Clamp Close Profile Block
- DYC DYC - Dynamic Command Block
- EAC - Ejector Advance Configuration Block
- EPC - Ejector Profile Block
- ERC - Ejector Retract Configuration Block
- FCC - First Clamp Close Configuration Block
- FOC - First Clamp Open Configuration Block
- HDC - Hold Configuration Block
- HPC - Pack/Hold Profile Block
- INC - Injection Configuration Block
- IPC - Injection Profile Block
- JGC - Jog Configuration Block
- LPC - Clamp Low Pressure Close Configuration Block
- MCC - Module Configuration Command Block
- OPC - Clamp Open Profile Block
- OSC - Clamp Open Slow Configuration Block
- PKC - Pack Configuration Block
- PLC Plastication Configuration Command Block (PLC)
- PPC - Plastication Profile Block
- PRC - Pre-decompression Configuration Block
- PSC - Post-decompression Configuration Block
- PTC - Process Trace Configuration Block
- RLC - Inject ERC Values Block
- SCC - Second Clamp Close Configuration Block
- SOC - Second Clamp Open Configuration Block
- TCC - Third Clamp Close Configuration Block
- TOC - Third Clamp Open Configuration Block
- 3 - Word/Bit Descriptions
- List of Status Blocks and Block ID Codes
- List of Data Words
- Data Blocks Require I/O Configuration
- Engineering Units
- Status Block for Reporting System Status
- Status Blocks for Reporting Ram (Screw) Position
- Status Blocks for Reporting Clamp Position
- Status Blocks for Reporting Ejector Position
- CLS - Clamp and Eject ERC Values Status Block
- CPS - Clamp Close Profiles Status Block
- EPS - Ejector Profile Status Block
- HPS - Pack/Hold Profile Status Block
- IPS ú Injection Profile Status Block
- OPS - Clamp Open Profiles Status Block
- PPS - Plastication Profile Status Block
- PTS - Process Trace Status Block
- RLS - Inject ERC Values Status Block
- SYS - System Status Block
- 4 - Programming Error Codes
- 5 - Module Specifications
- 6 - Calibration Instructions
- A - Single transfer for Reporting Ejector Status
- Back cover

4–49Programming Error Codes
Publication
1771-6.5.88 – July 1997
Error Code
Description
ID = 21
0633 Your OPC33 must be zero because TOC is invalid (SYS16-B02 = 0).
0634 Your OPC34 must be zero because TOC is invalid (SYS16-B02 = 0).
0635 Your OPC35 must be zero because TOC is invalid (SYS16-B02 = 0).
0812 OPC12 must be 00000 when OPC11 = 00000.
0813 OPC13 must be 00000 when OPC11 = 00000.
0814 OPC14 must be 00000 when OPC11 = 00000.
0815 OPC15 must be 00000 when OPC14 = 00000.
0816 OPC16 must be 00000 when OPC14 = 00000.
0817 OPC17 must be 00000 when OPC14 = 00000.
0821 OPC21 must be 00000 when OPC20 = 00000.
0822 OPC22 must be 00000 when OPC20 = 00000.
0823 OPC23 must be 00000 when OPC20 = 00000.
0824 OPC24 must be 00000 when OPC23 = 00000.
0825 OPC25 must be 00000 when OPC23 = 00000.
0826 OPC26 must be 00000 when OPC23 = 00000.
0830 OPC30 must be 00000 when OPC29 = 00000.
0831 OPC31 must be 00000 when OPC29 = 00000.
0832 OPC32 must be 00000 when OPC29 = 00000.
0833 OPC33 must be 00000 when OPC32 = 00000.
0834 OPC34 must be 00000 when OPC32 = 00000.
0835 OPC35 must be 00000 when OPC32 = 00000.
0839 OPC39 must be 00000 when OPC38 = 00000.
0840 OPC40 must be 00000 when OPC38 = 00000.
1014 OPC14 is not in increasing positional order.
If non-zero, OPC14 must be greater than OPC11.
1017 OPC17 is not in increasing positional order.
If non-zero, OPC17 must be greater than OPC14.
1020 OPC20 is not in increasing positional order.
If non-zero, OPC20 must be greater than OPC11, OPC14, and OPC17.
1023 OPC23 is not in increasing positional order.
If non-zero, OPC23 must be greater than OPC20.
1026 OPC26 is not in increasing positional order.
If non-zero, OPC26 must be greater than OPC23.
1029 OPC29 is not in increasing positional order. If non-zero, OPC29 must be greater than OPC11,
OPC14, OPC17, OPC20, OPC23, and OPC26.
1032 OPC32 is not in increasing positional order.
If non-zero, OPC32 must be greater than OPC29.
1035 OPC35 is not in increasing positional order.
If non-zero, OPC35 must be greater than OPC32.
1038 OPC38 is not in increasing positional order. If non-zero, OPC38 must be greater than OPC11,
OPC14, OPC17, OPC20, OPC23, OPC26, OPC29, OPC32, and OPC35.
0209
CLC09 is out of range. Valid range is 00000
≤
CLC09
≤
09999
0210
CLC10 is out of range. Valid range is 00000
≤
CLC10
≤
09999
0211
CLC11 is out of range. Valid range is 00000
≤
CLC11
≤
09999
0212
CLC12 is out of range. Valid range is 00000
≤
CLC12
≤
09999
0213
CLC13 is out of range. Valid range is 00000
≤
CLC13
≤
09999
0214
CLC14 is out of range. Valid range is 00000
≤
CLC14
≤
09999
0215
CLC15 is out of range. Valid range is 00000
≤
CLC15
≤
09999
0216
CLC16 is out of range. Valid range is 00000
≤
CLC16
≤
09999
0217
CLC17 is out of range. Valid range is 00000
≤
CLC17
≤
09999