- 1771-6.5.88, Plastic Molding Module Reference Manual
- Summary of Changes
- Table of Contents
- Preface
- 1 - Abbreviated Command and Status Blocks
- Chapter Contents
- CLC - Clamp and Eject ERC Values Block
- CPC - Clamp Close Profile Block
- DYC - Dynamic Command Block
- EAC - Ejector Advance Configuration Block
- EPC - Ejector Profile Block
- ERC - Ejector Retract Configuration Block
- FCC - First Clamp Close Configuration Block
- FOC - First Clamp Open Configuration Block
- HDC - Hold Configuration Block
- HPC - Pack/Hold Profile Block
- INC - Injection Configuration Block
- IPC - Injection Profile Block
- JGC - Jog Configuration Block
- LPC - Clamp Low Pressure Close Configuration Block
- MCC - Module Configuration Command Block
- OPC - Clamp Open Profile Block
- OSC - Clamp Open Slow Configuration Block
- PKC - Pack Configuration Block
- PLC - Plastication Configuration Block
- PPC - Plastication Profile Block
- PRC - Pre-decompression Configuration Block
- PSC - Post- decompression Configuration Block
- PTC - Process Trace Configuration Block
- RLC - Inject ERC Values Block
- SCC - Second Clamp Close Configuration Block
- SOC - Second Clamp Open Configuration Block
- TCC - Third Clamp Close Configuration Block
- TOC - Third Clamp Open Configuration Block
- CLS - Clamp and Eject ERC Values Status Block
- CPS - Clamp Close Profiles Status Block
- EPS - Ejector Profile Status Block
- HPS - Pack/Hold Profile Status Block
- IPS - Injection Profile Status Block
- OPS - Clamp Open Profiles Status Block
- PPS - Plastication Profile Status Block
- PTS - Process Trace Status Block
- RLS - Inject ERC Values Status Block
- SYS - System Status Block
- 2 - Command Word/Bit Descriptions
- Alphabetical List of Command Blocks and Block ID Codes
- List of Data Words
- Engineering Units
- Data Blocks Require I/O Configuration
- Data Blocks for System Control
- Data Blocks for Controlling Ram (Screw) Position
- Data Blocks for Controlling Clamp Position
- Data Blocks for Controlling Ejector Position
- Sensors Required
- CLC CLC - Clamp and Eject ERC Values Block
- CPC - Clamp Close Profile Block
- DYC DYC - Dynamic Command Block
- EAC - Ejector Advance Configuration Block
- EPC - Ejector Profile Block
- ERC - Ejector Retract Configuration Block
- FCC - First Clamp Close Configuration Block
- FOC - First Clamp Open Configuration Block
- HDC - Hold Configuration Block
- HPC - Pack/Hold Profile Block
- INC - Injection Configuration Block
- IPC - Injection Profile Block
- JGC - Jog Configuration Block
- LPC - Clamp Low Pressure Close Configuration Block
- MCC - Module Configuration Command Block
- OPC - Clamp Open Profile Block
- OSC - Clamp Open Slow Configuration Block
- PKC - Pack Configuration Block
- PLC Plastication Configuration Command Block (PLC)
- PPC - Plastication Profile Block
- PRC - Pre-decompression Configuration Block
- PSC - Post-decompression Configuration Block
- PTC - Process Trace Configuration Block
- RLC - Inject ERC Values Block
- SCC - Second Clamp Close Configuration Block
- SOC - Second Clamp Open Configuration Block
- TCC - Third Clamp Close Configuration Block
- TOC - Third Clamp Open Configuration Block
- 3 - Word/Bit Descriptions
- List of Status Blocks and Block ID Codes
- List of Data Words
- Data Blocks Require I/O Configuration
- Engineering Units
- Status Block for Reporting System Status
- Status Blocks for Reporting Ram (Screw) Position
- Status Blocks for Reporting Clamp Position
- Status Blocks for Reporting Ejector Position
- CLS - Clamp and Eject ERC Values Status Block
- CPS - Clamp Close Profiles Status Block
- EPS - Ejector Profile Status Block
- HPS - Pack/Hold Profile Status Block
- IPS ú Injection Profile Status Block
- OPS - Clamp Open Profiles Status Block
- PPS - Plastication Profile Status Block
- PTS - Process Trace Status Block
- RLS - Inject ERC Values Status Block
- SYS - System Status Block
- 4 - Programming Error Codes
- 5 - Module Specifications
- 6 - Calibration Instructions
- A - Single transfer for Reporting Ejector Status
- Back cover

4–38 Programming Error Codes
Publication
1771-6.5.88 – July 1997
Error Code
Description
ID = 15
1027 PPC27 is not in increasing positional order.
If non-zero, PPC27 must be greater than PPC23.
1031 PPC31 is not in increasing positional order.
If non-zero, PPC31 must be greater than PPC27.
1035 PPC35 is not in increasing positional order.
If non-zero, PPC35 must be greater than PPC31.
1039 PPC39 is not in increasing positional order.
If non-zero, PPC39 must be greater than PPC35.
1043 PPC43 is not in increasing positional order.
If non-zero, PPC43 must be greater than PPC39.
1047 PPC47 is not in increasing positional order.
If non-zero, PPC47 must be greater than PPC43.
ID = 16
PSC – Post-Decompression Configuration Block
Error Code
Description
ID = 16
0208
PSC08 is out of range. Valid range is 00000
≤
PSC08
≤
09999
0209
PSC09 is out of range. Valid range is 00000
≤
PSC09
≤
09999
0210
PSC10 is out of range. Valid range is 00000
≤
PSC10
≤
09999
0211
PSC11 is out of range. Valid range is 00000
≤
PSC11
≤
09999
0212
PSC12 is out of range. Valid range is 00000
≤
PSC12
≤
09999
0213
PSC13 is out of range. Valid range is 00000
≤
PSC13
≤
09999
0214
PSC14 is out of range. Valid range is 00000
≤
PSC14
≤
09999
0215
PSC15 is out of range. Valid range is 00000
≤
PSC15
≤
09999
0216
PSC16 is out of range. Valid range is 00000
≤
PSC16
≤
09999
0217
PSC17 is out of range. Valid range is 00000
≤
PSC17
≤
09999
0218
PSC18 is out of range. Valid range is 00000
≤
PSC18
≤
09999
0219
PSC19 is out of range. Valid range is 00000
≤
PSC19
≤
09999
0220
PSC20 is out of range. Valid range is 00000
≤
PSC20
≤
09999
0221
PSC21 is out of range. Valid range is 00000
≤
PSC21
≤
09999
0222
PSC22 is out of range. Valid range is 00000
≤
PSC22
≤
09999
0223
PSC23 is out of range. Valid range is 00000
≤
PSC23
≤
09999
0224
PSC24 is out of range. Valid range is 00000
≤
PSC24
≤
09999
0225
PSC25 is out of range. Valid range is 00000
≤
PSC25
≤
09999
0226
PSC26 is out of range. Valid range is 00000
≤
PSC26
≤
09999
0227
PSC27 is out of range. Valid range is 00000
≤
PSC27
≤
09999
0228
PSC28 is out of range. Valid range is 00000
≤
PSC28
≤
09999
0229
PSC29 is out of range. Valid range is 00000
≤
PSC29
≤
09999
0230
PSC30 is out of range. Valid range is 00000
≤
PSC30
≤
09999
0231
PSC31 is out of range. Valid range is 00000
≤
PSC31
≤
09999
0232
PSC32 is out of range. Valid range is 00000
≤
PSC32
≤
09999
0233
PSC33 is out of range. Valid range is 00000
≤
PSC33
≤
09999
0234
PSC34 is out of range. Valid range is 00000
≤
PSC34
≤
09999
0235
PSC35 is out of range. Valid range is 00000
≤
PSC35
≤
09999
0236
PSC36 is out of range. Valid range is 00000
≤
PSC36
≤
09999
0237
PSC37 is out of range. Valid range is 00000
≤
PSC37
≤
09999
0238
PSC38 is out of range. Valid range is 00000
≤
PSC38
≤
09999
0239
PSC39 is out of range. Valid range is 00000
≤
PSC39
≤
09999