User Manual
Table Of Contents
- 1771-6.5.88, Plastic Molding Module Reference Manual
- Summary of Changes
- Table of Contents
- Preface
- 1 - Abbreviated Command and Status Blocks
- Chapter Contents
- CLC - Clamp and Eject ERC Values Block
- CPC - Clamp Close Profile Block
- DYC - Dynamic Command Block
- EAC - Ejector Advance Configuration Block
- EPC - Ejector Profile Block
- ERC - Ejector Retract Configuration Block
- FCC - First Clamp Close Configuration Block
- FOC - First Clamp Open Configuration Block
- HDC - Hold Configuration Block
- HPC - Pack/Hold Profile Block
- INC - Injection Configuration Block
- IPC - Injection Profile Block
- JGC - Jog Configuration Block
- LPC - Clamp Low Pressure Close Configuration Block
- MCC - Module Configuration Command Block
- OPC - Clamp Open Profile Block
- OSC - Clamp Open Slow Configuration Block
- PKC - Pack Configuration Block
- PLC - Plastication Configuration Block
- PPC - Plastication Profile Block
- PRC - Pre-decompression Configuration Block
- PSC - Post- decompression Configuration Block
- PTC - Process Trace Configuration Block
- RLC - Inject ERC Values Block
- SCC - Second Clamp Close Configuration Block
- SOC - Second Clamp Open Configuration Block
- TCC - Third Clamp Close Configuration Block
- TOC - Third Clamp Open Configuration Block
- CLS - Clamp and Eject ERC Values Status Block
- CPS - Clamp Close Profiles Status Block
- EPS - Ejector Profile Status Block
- HPS - Pack/Hold Profile Status Block
- IPS - Injection Profile Status Block
- OPS - Clamp Open Profiles Status Block
- PPS - Plastication Profile Status Block
- PTS - Process Trace Status Block
- RLS - Inject ERC Values Status Block
- SYS - System Status Block
- 2 - Command Word/Bit Descriptions
- Alphabetical List of Command Blocks and Block ID Codes
- List of Data Words
- Engineering Units
- Data Blocks Require I/O Configuration
- Data Blocks for System Control
- Data Blocks for Controlling Ram (Screw) Position
- Data Blocks for Controlling Clamp Position
- Data Blocks for Controlling Ejector Position
- Sensors Required
- CLC CLC - Clamp and Eject ERC Values Block
- CPC - Clamp Close Profile Block
- DYC DYC - Dynamic Command Block
- EAC - Ejector Advance Configuration Block
- EPC - Ejector Profile Block
- ERC - Ejector Retract Configuration Block
- FCC - First Clamp Close Configuration Block
- FOC - First Clamp Open Configuration Block
- HDC - Hold Configuration Block
- HPC - Pack/Hold Profile Block
- INC - Injection Configuration Block
- IPC - Injection Profile Block
- JGC - Jog Configuration Block
- LPC - Clamp Low Pressure Close Configuration Block
- MCC - Module Configuration Command Block
- OPC - Clamp Open Profile Block
- OSC - Clamp Open Slow Configuration Block
- PKC - Pack Configuration Block
- PLC Plastication Configuration Command Block (PLC)
- PPC - Plastication Profile Block
- PRC - Pre-decompression Configuration Block
- PSC - Post-decompression Configuration Block
- PTC - Process Trace Configuration Block
- RLC - Inject ERC Values Block
- SCC - Second Clamp Close Configuration Block
- SOC - Second Clamp Open Configuration Block
- TCC - Third Clamp Close Configuration Block
- TOC - Third Clamp Open Configuration Block
- 3 - Word/Bit Descriptions
- List of Status Blocks and Block ID Codes
- List of Data Words
- Data Blocks Require I/O Configuration
- Engineering Units
- Status Block for Reporting System Status
- Status Blocks for Reporting Ram (Screw) Position
- Status Blocks for Reporting Clamp Position
- Status Blocks for Reporting Ejector Position
- CLS - Clamp and Eject ERC Values Status Block
- CPS - Clamp Close Profiles Status Block
- EPS - Ejector Profile Status Block
- HPS - Pack/Hold Profile Status Block
- IPS ú Injection Profile Status Block
- OPS - Clamp Open Profiles Status Block
- PPS - Plastication Profile Status Block
- PTS - Process Trace Status Block
- RLS - Inject ERC Values Status Block
- SYS - System Status Block
- 4 - Programming Error Codes
- 5 - Module Specifications
- 6 - Calibration Instructions
- A - Single transfer for Reporting Ejector Status
- Back cover

4–37Programming Error Codes
Publication
1771-6.5.88 – July 1997
Error Code
Description
ID = 15
0736 PPC36 cannot be 00000 when PPC38 > 00000.
0739 PPC39 cannot be 00000 when PPC42 > 00000.
0740 PPC40 cannot be 00000 when PPC42 > 00000.
0743 PPC43 cannot be 00000 when PPC46 > 00000.
0744 PPC44 cannot be 00000 when PPC46 > 00000.
0747 PPC47 cannot be 00000 when PPC50 > 00000.
0748 PPC48 cannot be 00000 when PPC50 > 00000.
0815 PPC15 must be 00000 when PPC11 = 00000.
0816 PPC16 must be 00000 when PPC12 = 00000.
0819 PPC19 must be 00000 when PPC15 = 00000.
0820 PPC20 must be 00000 when PPC16 = 00000.
0823 PPC23 must be 00000 when PPC19 = 00000.
0824 PPC24 must be 00000 when PPC20 = 00000.
0827 PPC27 must be 00000 when PPC23 = 00000.
0828 PPC28 must be 00000 when PPC24 = 00000.
0831 PPC31 must be 00000 when PPC27 = 00000.
0832 PPC32 must be 00000 when PPC28 = 00000.
0835 PPC35 must be 00000 when PPC31 = 00000.
0836 PPC36 must be 00000 when PPC32 = 00000.
0839 PPC39 must be 00000 when PPC35 = 00000.
0840 PPC40 must be 00000 when PPC36 = 00000.
0843 PPC43 must be 00000 when PPC39 = 00000.
0844 PPC44 must be 00000 when PPC40 = 00000.
0847 PPC47 must be 00000 when PPC43 = 00000.
0848 PPC48 must be 00000 when PPC44 = 00000.
0961 PPC61 is too large.
if: then:
MCC13 and MCC14 PPC61 must be within MCC13 + PPC61 + PRC05
≤
MCC14
are both non-zero
MCC13 is zero and PPC61 must be within MCC09 + PPC61 + PRC05
≤
MCC14
is non-zero
MCC13 is non-zero and PPC61 must be within MCC13 + PPC61 + PRC05
≤
MCC10
MCC14 is zero
MCC13 and MCC14 PPC61 must be within MCC09 + PPC61 + PRC05
≤
MCC10
are both zero
0962 PPC62 is too large.
if: then:
MCC13 and MCC14 PPC62 must be within MCC13 + PPC61 + PPC62 + PSC05
are both non-zero
≤
MCC14
MCC13 is zero and PPC62 must be within MCC09 + PPC61 + PPC62 + PSC05
MCC14 is non-zero
≤
MCC14
MCC13 is non-zero and PPC62 must be within MCC13 + PPC61 + PPC62 + PSC05
MCC14 is zero
≤
MCC10
MCC13 and MCC14 PPC62 must be within MCC09 + PPC61 + PPC62 + PSC05
are both zero
≤
MCC10
1015 PPC15 is not in increasing positional order.
If non-zero, PPC15 must be greater than PPC11.
1019 PPC19 is not in increasing positional order.
If non-zero, PPC19 must be greater than PPC15.
1023 PPC23 is not in increasing positional order.
If non-zero, PPC23 must be greater than PPC19.