User Manual
Table Of Contents
- 1771-6.5.88, Plastic Molding Module Reference Manual
- Summary of Changes
- Table of Contents
- Preface
- 1 - Abbreviated Command and Status Blocks
- Chapter Contents
- CLC - Clamp and Eject ERC Values Block
- CPC - Clamp Close Profile Block
- DYC - Dynamic Command Block
- EAC - Ejector Advance Configuration Block
- EPC - Ejector Profile Block
- ERC - Ejector Retract Configuration Block
- FCC - First Clamp Close Configuration Block
- FOC - First Clamp Open Configuration Block
- HDC - Hold Configuration Block
- HPC - Pack/Hold Profile Block
- INC - Injection Configuration Block
- IPC - Injection Profile Block
- JGC - Jog Configuration Block
- LPC - Clamp Low Pressure Close Configuration Block
- MCC - Module Configuration Command Block
- OPC - Clamp Open Profile Block
- OSC - Clamp Open Slow Configuration Block
- PKC - Pack Configuration Block
- PLC - Plastication Configuration Block
- PPC - Plastication Profile Block
- PRC - Pre-decompression Configuration Block
- PSC - Post- decompression Configuration Block
- PTC - Process Trace Configuration Block
- RLC - Inject ERC Values Block
- SCC - Second Clamp Close Configuration Block
- SOC - Second Clamp Open Configuration Block
- TCC - Third Clamp Close Configuration Block
- TOC - Third Clamp Open Configuration Block
- CLS - Clamp and Eject ERC Values Status Block
- CPS - Clamp Close Profiles Status Block
- EPS - Ejector Profile Status Block
- HPS - Pack/Hold Profile Status Block
- IPS - Injection Profile Status Block
- OPS - Clamp Open Profiles Status Block
- PPS - Plastication Profile Status Block
- PTS - Process Trace Status Block
- RLS - Inject ERC Values Status Block
- SYS - System Status Block
- 2 - Command Word/Bit Descriptions
- Alphabetical List of Command Blocks and Block ID Codes
- List of Data Words
- Engineering Units
- Data Blocks Require I/O Configuration
- Data Blocks for System Control
- Data Blocks for Controlling Ram (Screw) Position
- Data Blocks for Controlling Clamp Position
- Data Blocks for Controlling Ejector Position
- Sensors Required
- CLC CLC - Clamp and Eject ERC Values Block
- CPC - Clamp Close Profile Block
- DYC DYC - Dynamic Command Block
- EAC - Ejector Advance Configuration Block
- EPC - Ejector Profile Block
- ERC - Ejector Retract Configuration Block
- FCC - First Clamp Close Configuration Block
- FOC - First Clamp Open Configuration Block
- HDC - Hold Configuration Block
- HPC - Pack/Hold Profile Block
- INC - Injection Configuration Block
- IPC - Injection Profile Block
- JGC - Jog Configuration Block
- LPC - Clamp Low Pressure Close Configuration Block
- MCC - Module Configuration Command Block
- OPC - Clamp Open Profile Block
- OSC - Clamp Open Slow Configuration Block
- PKC - Pack Configuration Block
- PLC Plastication Configuration Command Block (PLC)
- PPC - Plastication Profile Block
- PRC - Pre-decompression Configuration Block
- PSC - Post-decompression Configuration Block
- PTC - Process Trace Configuration Block
- RLC - Inject ERC Values Block
- SCC - Second Clamp Close Configuration Block
- SOC - Second Clamp Open Configuration Block
- TCC - Third Clamp Close Configuration Block
- TOC - Third Clamp Open Configuration Block
- 3 - Word/Bit Descriptions
- List of Status Blocks and Block ID Codes
- List of Data Words
- Data Blocks Require I/O Configuration
- Engineering Units
- Status Block for Reporting System Status
- Status Blocks for Reporting Ram (Screw) Position
- Status Blocks for Reporting Clamp Position
- Status Blocks for Reporting Ejector Position
- CLS - Clamp and Eject ERC Values Status Block
- CPS - Clamp Close Profiles Status Block
- EPS - Ejector Profile Status Block
- HPS - Pack/Hold Profile Status Block
- IPS ú Injection Profile Status Block
- OPS - Clamp Open Profiles Status Block
- PPS - Plastication Profile Status Block
- PTS - Process Trace Status Block
- RLS - Inject ERC Values Status Block
- SYS - System Status Block
- 4 - Programming Error Codes
- 5 - Module Specifications
- 6 - Calibration Instructions
- A - Single transfer for Reporting Ejector Status
- Back cover

4–30 Programming Error Codes
Publication
1771-6.5.88 – July 1997
Error Code
Description
ID = 12
0810 HPC10 must be 00000 when HPC11 = 00000.
0812 HPC12 must be 00000 when HPC14 = 00000.
0813 HPC13 must be 00000 when HPC14 = 00000.
0815 HPC15 must be 00000 when HPC17 = 00000.
0816 HPC16 must be 00000 when HPC17 = 00000.
0818 HPC18 must be 00000 when HPC20 = 00000.
0819 HPC19 must be 00000 when HPC20 = 00000.
0821 HPC21 must be 00000 when HPC23 = 00000.
0822 HPC22 must be 00000 when HPC23 = 00000.
0829 HPC29 must be 00000 when HPC31 = 00000.
0830 HPC30 must be 00000 when HPC31 = 00000.
0832 HPC32 must be 00000 when HPC34 = 00000.
0833 HPC33 must be 00000 when HPC34 = 00000.
0835 HPC35 must be 00000 when HPC37 = 00000.
0836 HPC36 must be 00000 when HPC37 = 00000.
0838 HPC38 must be 00000 when HPC40 = 00000.
0839 HPC39 must be 00000 when HPC40 = 00000.
ID = 13
PRC – Pre-Decompression Configuration Block
Error Code
Description
ID = 13
0208
PRC08 is out of range. Valid range is 00000
≤
PRC08
≤
09999
0209
PRC09 is out of range. Valid range is 00000
≤
PRC09
≤
09999
0210
PRC10 is out of range. Valid range is 00000
≤
PRC10
≤
09999
0211
PRC11 is out of range. Valid range is 00000
≤
PRC11
≤
09999
0212
PRC12 is out of range. Valid range is 00000
≤
PRC12
≤
09999
0213
PRC13 is out of range. Valid range is 00000
≤
PRC13
≤
09999
0214
PRC14 is out of range. Valid range is 00000
≤
PRC14
≤
09999
0215
PRC15 is out of range. Valid range is 00000
≤
PRC15
≤
09999
0216
PRC16 is out of range. Valid range is 00000
≤
PRC16
≤
09999
0217
PRC17 is out of range. Valid range is 00000
≤
PRC17
≤
09999
0218
PRC18 is out of range. Valid range is 00000
≤
PRC18
≤
09999
0219
PRC19 is out of range. Valid range is 00000
≤
PRC19
≤
09999
0220
PRC20 is out of range. Valid range is 00000
≤
PRC20
≤
09999
0221
PRC21 is out of range. Valid range is 00000
≤
PRC21
≤
09999
0222
PRC22 is out of range. Valid range is 00000
≤
PRC22
≤
09999
0223
PRC23 is out of range. Valid range is 00000
≤
PRC23
≤
09999
0224
PRC24 is out of range. Valid range is 00000
≤
PRC24
≤
09999
0225
PRC25 is out of range. Valid range is 00000
≤
PRC25
≤
09999
0226
PRC25 is out of range. Valid range is 00000
≤
PRC26
≤
09999
0227
PRC27 is out of range. Valid range is 00000
≤
PRC27
≤
09999
0228
PRC28 is out of range. Valid range is 00000
≤
PRC28
≤
09999
0229
PRC29 is out of range. Valid range is 00000
≤
PRC29
≤
09999
0230
PRC30 is out of range. Valid range is 00000
≤
PRC30
≤
09999
0231
PRC31 is out of range. Valid range is 00000
≤
PRC31
≤
09999
0232
PRC32 is out of range. Valid range is 00000
≤
PRC32
≤
09999