User Manual
Table Of Contents
- 1771-6.5.88, Plastic Molding Module Reference Manual
- Summary of Changes
- Table of Contents
- Preface
- 1 - Abbreviated Command and Status Blocks
- Chapter Contents
- CLC - Clamp and Eject ERC Values Block
- CPC - Clamp Close Profile Block
- DYC - Dynamic Command Block
- EAC - Ejector Advance Configuration Block
- EPC - Ejector Profile Block
- ERC - Ejector Retract Configuration Block
- FCC - First Clamp Close Configuration Block
- FOC - First Clamp Open Configuration Block
- HDC - Hold Configuration Block
- HPC - Pack/Hold Profile Block
- INC - Injection Configuration Block
- IPC - Injection Profile Block
- JGC - Jog Configuration Block
- LPC - Clamp Low Pressure Close Configuration Block
- MCC - Module Configuration Command Block
- OPC - Clamp Open Profile Block
- OSC - Clamp Open Slow Configuration Block
- PKC - Pack Configuration Block
- PLC - Plastication Configuration Block
- PPC - Plastication Profile Block
- PRC - Pre-decompression Configuration Block
- PSC - Post- decompression Configuration Block
- PTC - Process Trace Configuration Block
- RLC - Inject ERC Values Block
- SCC - Second Clamp Close Configuration Block
- SOC - Second Clamp Open Configuration Block
- TCC - Third Clamp Close Configuration Block
- TOC - Third Clamp Open Configuration Block
- CLS - Clamp and Eject ERC Values Status Block
- CPS - Clamp Close Profiles Status Block
- EPS - Ejector Profile Status Block
- HPS - Pack/Hold Profile Status Block
- IPS - Injection Profile Status Block
- OPS - Clamp Open Profiles Status Block
- PPS - Plastication Profile Status Block
- PTS - Process Trace Status Block
- RLS - Inject ERC Values Status Block
- SYS - System Status Block
- 2 - Command Word/Bit Descriptions
- Alphabetical List of Command Blocks and Block ID Codes
- List of Data Words
- Engineering Units
- Data Blocks Require I/O Configuration
- Data Blocks for System Control
- Data Blocks for Controlling Ram (Screw) Position
- Data Blocks for Controlling Clamp Position
- Data Blocks for Controlling Ejector Position
- Sensors Required
- CLC CLC - Clamp and Eject ERC Values Block
- CPC - Clamp Close Profile Block
- DYC DYC - Dynamic Command Block
- EAC - Ejector Advance Configuration Block
- EPC - Ejector Profile Block
- ERC - Ejector Retract Configuration Block
- FCC - First Clamp Close Configuration Block
- FOC - First Clamp Open Configuration Block
- HDC - Hold Configuration Block
- HPC - Pack/Hold Profile Block
- INC - Injection Configuration Block
- IPC - Injection Profile Block
- JGC - Jog Configuration Block
- LPC - Clamp Low Pressure Close Configuration Block
- MCC - Module Configuration Command Block
- OPC - Clamp Open Profile Block
- OSC - Clamp Open Slow Configuration Block
- PKC - Pack Configuration Block
- PLC Plastication Configuration Command Block (PLC)
- PPC - Plastication Profile Block
- PRC - Pre-decompression Configuration Block
- PSC - Post-decompression Configuration Block
- PTC - Process Trace Configuration Block
- RLC - Inject ERC Values Block
- SCC - Second Clamp Close Configuration Block
- SOC - Second Clamp Open Configuration Block
- TCC - Third Clamp Close Configuration Block
- TOC - Third Clamp Open Configuration Block
- 3 - Word/Bit Descriptions
- List of Status Blocks and Block ID Codes
- List of Data Words
- Data Blocks Require I/O Configuration
- Engineering Units
- Status Block for Reporting System Status
- Status Blocks for Reporting Ram (Screw) Position
- Status Blocks for Reporting Clamp Position
- Status Blocks for Reporting Ejector Position
- CLS - Clamp and Eject ERC Values Status Block
- CPS - Clamp Close Profiles Status Block
- EPS - Ejector Profile Status Block
- HPS - Pack/Hold Profile Status Block
- IPS ú Injection Profile Status Block
- OPS - Clamp Open Profiles Status Block
- PPS - Plastication Profile Status Block
- PTS - Process Trace Status Block
- RLS - Inject ERC Values Status Block
- SYS - System Status Block
- 4 - Programming Error Codes
- 5 - Module Specifications
- 6 - Calibration Instructions
- A - Single transfer for Reporting Ejector Status
- Back cover

4–28 Programming Error Codes
Publication
1771-6.5.88 – July 1997
ID = 12
HPC – Pack/Hold Profile Block
Error Code
Description
ID = 12
0211
HPC11 is out of range. Valid range is 00000
≤
HPC11
≤
09999
0214
HPC14 is out of range. Valid range is 00000
≤
HPC14
≤
09999
0217
HPC17 is out of range. Valid range is 00000
≤
HPC17
≤
09999
0220
HPC20 is out of range. Valid range is 00000
≤
HPC20
≤
09999
0223
HPC23 is out of range. Valid range is 00000
≤
HPC23
≤
09999
0228
HPC28 is out of range. Valid range is 00000
≤
HPC28
≤
09999
0231
HPC31 is out of range. Valid range is 00000
≤
HPC31
≤
09999
0234
HPC34 is out of range. Valid range is 00000
≤
HPC34
≤
09999
0237
HPC37 is out of range. Valid range is 00000
≤
HPC37
≤
09999
0240
HPC40 is out of range. Valid range is 00000
≤
HPC40
≤
09999
0261
HPC61 is out of range. Valid range is 00000
≤
HPC61
≤
09999
0409 HPC09 is out of range.
If non-zero, HPC09 must be within PKC45
≤
HPC09
≤
PKC46
0410 HPC10 is out of range.
If non-zero, HPC10 must be within PKC41
≤
HPC10
≤
PKC42
0412 HPC12 is out of range.
If non-zero, HPC12 must be within PKC45
≤
HPC12
≤
PKC46
0413 HPC13 is out of range.
If non-zero, HPC13 must be within PKC41
≤
HPC13
≤
PKC42
0415 HPC15 is out of range.
If non-zero, HPC15 must be within PKC45
≤
HPC15
≤
PKC46
0416 HPC16 is out of range.
If non-zero, HPC16 must be within PKC41
≤
HPC16
≤
PKC42
0418 HPC18 is out of range.
If non-zero, HPC18 must be within PKC45
≤
HPC18
≤
PKC46
0419 HPC19 is out of range.
If non-zero, HPC19 must be within PKC41
≤
HPC19
≤
PKC42
0421 HPC21 is out of range.
If non-zero, HPC21 must be within PKC45
≤
HPC21
≤
PKC46
0422 HPC22 is out of range.
If non-zero, HPC22 must be within PKC41
≤
HPC22
≤
PKC42
0424
HPC24 is out of range. Valid range is 00000
≤
HPC24
≤
PKC46
0425
HPC25 is out of range. Valid range is 00000
≤
HPC25
≤
PKC42
0426 HPC26 is out of range.
If non-zero, HPC26 must be within HDC45
≤
HPC26
≤
HDC46
0427 HPC27 is out of range.
If non-zero, HPC27 must be within HDC41
≤
HPC27
≤
HDC42
0429 HPC29 is out of range.
If non-zero, HPC29 must be within HDC45
≤
HPC29
≤
HDC46
0430 HPC30 is out of range.
If non-zero, HPC30 must be within HDC41
≤
HPC30
≤
HDC42
0432 HPC32 is out of range.
If non-zero, HPC32 must be within HDC45
≤
HPC32
≤
HDC46
0433 HPC33 is out of range.
If non-zero, HPC33 must be within HDC41
≤
HPC33
≤
HDC42
0435 HPC35 is out of range.
If non-zero, HPC35 must be within HDC45
≤
HPC35
≤
HDC46
0436 HPC36 is out of range.
If non-zero, HPC36 must be within HDC41
≤
HPC36
≤
HDC42