4–16 Programming Error Codes
Publication
1771-6.5.88 – July 1997
Error Code
Description
ID = 7
0503 Your selection to bridge the First Clamp Close Profile directly into the Second Clamp Close
Profile, and set-output upon conclusion of the Second Clamp Close Profile (CPC03-B08 = 0
and CPC03-B09 = 1) is invalid because the QDC module does not have a valid SCC on-board
(SYS15-B03 = 0).
0507 Your selection to bridge the first two Clamp Close Profiles directly into the Third Clamp Close
Profile, and set-output upon conclusion of the Third Clamp Close Profile (CPC03-B08 = 0,
CPC03-B09 = 0, and CPC03-B10 = 1) is invalid because the QDC module does not have a
valid TCC on-board (SYS15-B04 = 0).
0508 You have selected closed-loop Press/Pos execution for the Second Clamp Close Profile by
CPC04-B03 = 0; however, your bit patterns in MCC02 and MCC03 indicate that the QDC
module does not have access to a connected clamp pressure transducer.
0511 Your selection to bridge the Second Clamp Close Profile directly into the Third Clamp Close
Profile, and set-output upon conclusion of the Third Clamp Close Profile (CPC03-B09 = 0, and
CPC03-B10 = 1) is invalid because the QDC module does not have a valid TCC on-board
(SYS15-B04 = 0).
0512 You have selected closed-loop Press/Pos execution for the Third Clamp Close Profile by
CPC04-B05 = 0; however, your bit patterns in MCC02 and MCC03 indicate that the QDC
module does not have access to a connected clamp pressure transducer.
0516 You have selected closed-loop Press/Pos execution for the Clamp Low Pressure Close Profile
by CPC04-B07 = 0; however, your bit patterns in MCC02 and MCC03 indicate that the QDC
module does not have access to a connected clamp pressure transducer.
0600 Your entire Clamp Close Profile Command Block has been rejected because the QDC module
does not have a valid Clamp Low Pressure Close Configuration Command Block on-board
(SYS15-B05 = 0).
0609 Your CPC09 must be zero because of invalid FCC. (SYS15-B02 = 0).
0610 Your CPC10 must be zero because of invalid FCC. (SYS15-B02 = 0).
0611 Your CPC11 must be zero because of invalid FCC. (SYS15-B02 = 0).
0612 Your CPC12 must be zero because of invalid FCC. (SYS15-B02 = 0).
0613 Your CPC13 must be zero because of invalid FCC. (SYS15-B02 = 0).
0614 Your CPC14 must be zero because of invalid FCC. (SYS15-B02 = 0).
0615 Your CPC15 must be zero because of invalid FCC. (SYS15-B02 = 0).
0616 Your CPC16 must be zero because of invalid FCC. (SYS15-B02 = 0).
0617 Your CPC17 must be zero because of invalid FCC. (SYS15-B02 = 0).
0618 Your CPC18 must be zero because of invalid SCC. (SYS15-B03 = 0).
0619 Your CPC19 must be zero because of invalid SCC. (SYS15-B03 = 0).
0620 Your CPC20 must be zero because of invalid SCC. (SYS15-B03 = 0).
0621 Your CPC21 must be zero because of invalid SCC. (SYS15-B03 = 0).
0622 Your CPC22 must be zero because of invalid SCC. (SYS15-B03 = 0).
0623 Your CPC23 must be zero because of invalid SCC. (SYS15-B03 = 0).
0624 Your CPC24 must be zero because of invalid SCC. (SYS15-B03 = 0).
0625 Your CPC25 must be zero because of invalid SCC. (SYS15-B03 = 0).
0626 Your CPC26 must be zero because of invalid SCC. (SYS15-B03 = 0).
0627 Your CPC27 must be zero because of invalid TCC. (SYS15-B04 = 0).
0628 Your CPC28 must be zero because of invalid TCC. (SYS15-B04 = 0).
0629 Your CPC29 must be zero because of invalid TCC. (SYS15-B04 = 0).
0630 Your CPC30 must be zero because of invalid TCC. (SYS15-B04 = 0).
0631 Your CPC31 must be zero because of invalid TCC. (SYS15-B04 = 0).
0632 Your CPC32 must be zero because of invalid TCC. (SYS15-B04 = 0).
0633 Your CPC33 must be zero because of invalid TCC. (SYS15-B04 = 0).
0634 Your CPC34 must be zero because of invalid TCC. (SYS15-B04 = 0).
0635 Your CPC35 must be zero because of invalid TCC. (SYS15-B04 = 0).
0812 CPC12 must be 00000 when CPC11 = 00000.