User Manual
Table Of Contents
- 1771-6.5.88, Plastic Molding Module Reference Manual
- Summary of Changes
- Table of Contents
- Preface
- 1 - Abbreviated Command and Status Blocks
- Chapter Contents
- CLC - Clamp and Eject ERC Values Block
- CPC - Clamp Close Profile Block
- DYC - Dynamic Command Block
- EAC - Ejector Advance Configuration Block
- EPC - Ejector Profile Block
- ERC - Ejector Retract Configuration Block
- FCC - First Clamp Close Configuration Block
- FOC - First Clamp Open Configuration Block
- HDC - Hold Configuration Block
- HPC - Pack/Hold Profile Block
- INC - Injection Configuration Block
- IPC - Injection Profile Block
- JGC - Jog Configuration Block
- LPC - Clamp Low Pressure Close Configuration Block
- MCC - Module Configuration Command Block
- OPC - Clamp Open Profile Block
- OSC - Clamp Open Slow Configuration Block
- PKC - Pack Configuration Block
- PLC - Plastication Configuration Block
- PPC - Plastication Profile Block
- PRC - Pre-decompression Configuration Block
- PSC - Post- decompression Configuration Block
- PTC - Process Trace Configuration Block
- RLC - Inject ERC Values Block
- SCC - Second Clamp Close Configuration Block
- SOC - Second Clamp Open Configuration Block
- TCC - Third Clamp Close Configuration Block
- TOC - Third Clamp Open Configuration Block
- CLS - Clamp and Eject ERC Values Status Block
- CPS - Clamp Close Profiles Status Block
- EPS - Ejector Profile Status Block
- HPS - Pack/Hold Profile Status Block
- IPS - Injection Profile Status Block
- OPS - Clamp Open Profiles Status Block
- PPS - Plastication Profile Status Block
- PTS - Process Trace Status Block
- RLS - Inject ERC Values Status Block
- SYS - System Status Block
- 2 - Command Word/Bit Descriptions
- Alphabetical List of Command Blocks and Block ID Codes
- List of Data Words
- Engineering Units
- Data Blocks Require I/O Configuration
- Data Blocks for System Control
- Data Blocks for Controlling Ram (Screw) Position
- Data Blocks for Controlling Clamp Position
- Data Blocks for Controlling Ejector Position
- Sensors Required
- CLC CLC - Clamp and Eject ERC Values Block
- CPC - Clamp Close Profile Block
- DYC DYC - Dynamic Command Block
- EAC - Ejector Advance Configuration Block
- EPC - Ejector Profile Block
- ERC - Ejector Retract Configuration Block
- FCC - First Clamp Close Configuration Block
- FOC - First Clamp Open Configuration Block
- HDC - Hold Configuration Block
- HPC - Pack/Hold Profile Block
- INC - Injection Configuration Block
- IPC - Injection Profile Block
- JGC - Jog Configuration Block
- LPC - Clamp Low Pressure Close Configuration Block
- MCC - Module Configuration Command Block
- OPC - Clamp Open Profile Block
- OSC - Clamp Open Slow Configuration Block
- PKC - Pack Configuration Block
- PLC Plastication Configuration Command Block (PLC)
- PPC - Plastication Profile Block
- PRC - Pre-decompression Configuration Block
- PSC - Post-decompression Configuration Block
- PTC - Process Trace Configuration Block
- RLC - Inject ERC Values Block
- SCC - Second Clamp Close Configuration Block
- SOC - Second Clamp Open Configuration Block
- TCC - Third Clamp Close Configuration Block
- TOC - Third Clamp Open Configuration Block
- 3 - Word/Bit Descriptions
- List of Status Blocks and Block ID Codes
- List of Data Words
- Data Blocks Require I/O Configuration
- Engineering Units
- Status Block for Reporting System Status
- Status Blocks for Reporting Ram (Screw) Position
- Status Blocks for Reporting Clamp Position
- Status Blocks for Reporting Ejector Position
- CLS - Clamp and Eject ERC Values Status Block
- CPS - Clamp Close Profiles Status Block
- EPS - Ejector Profile Status Block
- HPS - Pack/Hold Profile Status Block
- IPS ú Injection Profile Status Block
- OPS - Clamp Open Profiles Status Block
- PPS - Plastication Profile Status Block
- PTS - Process Trace Status Block
- RLS - Inject ERC Values Status Block
- SYS - System Status Block
- 4 - Programming Error Codes
- 5 - Module Specifications
- 6 - Calibration Instructions
- A - Single transfer for Reporting Ejector Status
- Back cover

4–7Programming Error Codes
Publication
1771-6.5.88 – July 1997
Error Code
Description
ID = 2
0244
JGC44 is out of range. Valid range is 00000
≤
JGC44
≤
09999
0245
JGC45 is out of range. Valid range is 00000
≤
JGC45
≤
09999
0246
JGC46 is out of range. Valid range is 00000
≤
JGC46
≤
09999
0247
JGC47 is out of range. Valid range is 00000
≤
JGC47
≤
09999
0248
JGC48 is out of range. Valid range is 00000
≤
JGC48
≤
09999
0249
JGC49 is out of range. Valid range is 00000
≤
JGC49
≤
09999
0250
JGC50 is out of range. Valid range is 00000
≤
JGC50
≤
09999
0251
JGC51 is out of range. Valid range is 00000
≤
JGC51
≤
09999
0252
JGC52 is out of range. Valid range is 00000
≤
JGC52
≤
09999
0253
JGC53 is out of range. Valid range is 00000
≤
JGC53
≤
09999
0254
JGC54 is out of range. Valid range is 00000
≤
JGC54
≤
09999
0255
JGC55 is out of range. Valid range is 00000
≤
JGC55
≤
09999
0256
JGC56 is out of range. Valid range is 00000
≤
JGC56
≤
09999
0257
JGC57 is out of range. Valid range is 00000
≤
JGC57
≤
09999
0258
JGC58 is out of range. Valid range is 00000
≤
JGC58
≤
09999
0259
JGC59 is out of range. Valid range is 00000
≤
JGC59
≤
09999
0260
JGC60 is out of range. Valid range is 00000
≤
JGC60
≤
09999
0261
JGC61 is out of range. Valid range is 00000
≤
JGC61
≤
09999
0262
JGC62 is out of range. Valid range is 00000
≤
JGC62
≤
09999
0263
JGC63 is out of range. Valid range is 00000
≤
JGC63
≤
09999
0264
JGC64 is out of range. Valid range is 00000
≤
JGC64
≤
09999
0405 JGC05 is out of range.
If non-zero, JGC05 must be within MCC51 < JGC05
≤
MCC52
0406 JGC06 is out of range.
If non-zero, JGC06 must be within MCC17 < JGC06
≤
MCC18
0407 JGC07 is out of range.
If non-zero, JGC07 must be within MCC31 < JGC07
≤
MCC32
0408 JGC08 is out of range.
If non-zero, JGC08 must be within MCC45 < JGC08
≤
MCC46
ID = 3
FCC – First Clamp Close Configuration Block
Error Code
Description
ID = 3
0205
FCC05 is out of range. Valid range is 00000
≤
FCC05
≤
09999
0206
FCC06 is out of range. Valid range is 00000
≤
FCC06
≤
09999
0208
FCC08 is out of range. Valid range is 00000
≤
FCC08
≤
09999
0209
FCC09 is out of range. Valid range is 00000
≤
FCC09
≤
09999
0210
FCC10 is out of range. Valid range is 00000
≤
FCC10
≤
09999
0211
FCC11 is out of range. Valid range is 00000
≤
FCC11
≤
09999
0212
FCC12 is out of range. Valid range is 00000
≤
FCC12
≤
09999
0213
FCC13 is out of range. Valid range is 00000
≤
FCC13
≤
09999
0214
FCC14 is out of range. Valid range is 00000
≤
FCC14
≤
09999
0215
FCC15 is out of range. Valid range is 00000
≤
FCC15
≤
09999
0216
FCC16 is out of range. Valid range is 00000
≤
FCC16
≤
09999
0217
FCC17 is out of range. Valid range is 00000
≤
FCC17
≤
09999
0218
FCC18 is out of range. Valid range is 00000
≤
FCC18
≤
09999
0219
FCC19 is out of range. Valid range is 00000
≤
FCC19
≤
09999