User Manual
Table Of Contents
- 1771-6.5.88, Plastic Molding Module Reference Manual
- Summary of Changes
- Table of Contents
- Preface
- 1 - Abbreviated Command and Status Blocks
- Chapter Contents
- CLC - Clamp and Eject ERC Values Block
- CPC - Clamp Close Profile Block
- DYC - Dynamic Command Block
- EAC - Ejector Advance Configuration Block
- EPC - Ejector Profile Block
- ERC - Ejector Retract Configuration Block
- FCC - First Clamp Close Configuration Block
- FOC - First Clamp Open Configuration Block
- HDC - Hold Configuration Block
- HPC - Pack/Hold Profile Block
- INC - Injection Configuration Block
- IPC - Injection Profile Block
- JGC - Jog Configuration Block
- LPC - Clamp Low Pressure Close Configuration Block
- MCC - Module Configuration Command Block
- OPC - Clamp Open Profile Block
- OSC - Clamp Open Slow Configuration Block
- PKC - Pack Configuration Block
- PLC - Plastication Configuration Block
- PPC - Plastication Profile Block
- PRC - Pre-decompression Configuration Block
- PSC - Post- decompression Configuration Block
- PTC - Process Trace Configuration Block
- RLC - Inject ERC Values Block
- SCC - Second Clamp Close Configuration Block
- SOC - Second Clamp Open Configuration Block
- TCC - Third Clamp Close Configuration Block
- TOC - Third Clamp Open Configuration Block
- CLS - Clamp and Eject ERC Values Status Block
- CPS - Clamp Close Profiles Status Block
- EPS - Ejector Profile Status Block
- HPS - Pack/Hold Profile Status Block
- IPS - Injection Profile Status Block
- OPS - Clamp Open Profiles Status Block
- PPS - Plastication Profile Status Block
- PTS - Process Trace Status Block
- RLS - Inject ERC Values Status Block
- SYS - System Status Block
- 2 - Command Word/Bit Descriptions
- Alphabetical List of Command Blocks and Block ID Codes
- List of Data Words
- Engineering Units
- Data Blocks Require I/O Configuration
- Data Blocks for System Control
- Data Blocks for Controlling Ram (Screw) Position
- Data Blocks for Controlling Clamp Position
- Data Blocks for Controlling Ejector Position
- Sensors Required
- CLC CLC - Clamp and Eject ERC Values Block
- CPC - Clamp Close Profile Block
- DYC DYC - Dynamic Command Block
- EAC - Ejector Advance Configuration Block
- EPC - Ejector Profile Block
- ERC - Ejector Retract Configuration Block
- FCC - First Clamp Close Configuration Block
- FOC - First Clamp Open Configuration Block
- HDC - Hold Configuration Block
- HPC - Pack/Hold Profile Block
- INC - Injection Configuration Block
- IPC - Injection Profile Block
- JGC - Jog Configuration Block
- LPC - Clamp Low Pressure Close Configuration Block
- MCC - Module Configuration Command Block
- OPC - Clamp Open Profile Block
- OSC - Clamp Open Slow Configuration Block
- PKC - Pack Configuration Block
- PLC Plastication Configuration Command Block (PLC)
- PPC - Plastication Profile Block
- PRC - Pre-decompression Configuration Block
- PSC - Post-decompression Configuration Block
- PTC - Process Trace Configuration Block
- RLC - Inject ERC Values Block
- SCC - Second Clamp Close Configuration Block
- SOC - Second Clamp Open Configuration Block
- TCC - Third Clamp Close Configuration Block
- TOC - Third Clamp Open Configuration Block
- 3 - Word/Bit Descriptions
- List of Status Blocks and Block ID Codes
- List of Data Words
- Data Blocks Require I/O Configuration
- Engineering Units
- Status Block for Reporting System Status
- Status Blocks for Reporting Ram (Screw) Position
- Status Blocks for Reporting Clamp Position
- Status Blocks for Reporting Ejector Position
- CLS - Clamp and Eject ERC Values Status Block
- CPS - Clamp Close Profiles Status Block
- EPS - Ejector Profile Status Block
- HPS - Pack/Hold Profile Status Block
- IPS ú Injection Profile Status Block
- OPS - Clamp Open Profiles Status Block
- PPS - Plastication Profile Status Block
- PTS - Process Trace Status Block
- RLS - Inject ERC Values Status Block
- SYS - System Status Block
- 4 - Programming Error Codes
- 5 - Module Specifications
- 6 - Calibration Instructions
- A - Single transfer for Reporting Ejector Status
- Back cover

3–15Status Word/Bit Descriptions
Publication
1771-6.5.88 – July 1997
IPS
Word Bit Description
B06 Segment 7
B07 Segment 8
B08 Segment 9
B09 Segment 10
B10 Segment 11
B11-B15 Open
IPS08 CV Low Limit Alarms
The module latches each bit when executing the subject profile segment in closed loop, and drives its algorithm CV to
minimum (0%) in an attempt to control the profile setpoint.
The module unlatches each bit when it completes execution of the subject profile segment in open loop, or in closed
loop without driving its algorithm CV to minimum (0%).
When this bit
is latched ON:
algorithm CV
is maximum during:
B00 Segment 1
B01 Segment 2
B02 Segment 3
B03 Segment 4
B04 Segment 5
B05 Segment 6
B06 Segment 7
B07 Segment 8
B08 Segment 9
B09 Segment 10
B10 Segment 11
B11-B15 Open
Injection Profile Actuals
Word Description
IPS09 Actual Segment 1 Velocity [05] or [06] Average ram (screw) velocity during last Segment 1.
If IPC03-B14 is RESET, the module reports this average in percent velocity.
If IPC03-B14 is SET, it reports it in in.(mm)/s.
IPS10 Actual Segment 1 Pressure [01] Average ram (screw) pressure during last Segment 1.
IPS11 Actual Segment 1 Execution Time [21] Time required for last Segment 1.
IPS12 Actual End of Segment 1 Position [12] Ram (Screw) position at completion of last Segment 1.
IPS13 Actual Segment 2 Velocity [05] or [06] Average ram (screw) velocity during last Segment 2.
If IPC03-B14 is RESET, the module reports this average in percent velocity.
If IPC03-B14 is SET, it reports it in in.(mm)/s.
IPS14 Actual Segment 2 Pressure [01] Average ram (screw) pressure during last Segment 2.
IPS15 Actual Segment 2 Execution Time [21] Time required for last Segment 2.
IPS16 Actual End of Segment 2 Position [12] Ram (Screw) position at completion of last Segment 2.
IPS17 Actual Segment 3 Velocity [05] or [06] Average ram (screw) velocity during last Segment 3.
If IPC03-B14 is RESET, the module reports this average in percent velocity.
If IPC03-B14 is SET, it reports it in in.(mm)/s.
IPS18 Actual Segment 3 Pressure [01] Average ram (screw) pressure during last Segment 3.
IPS19 Actual Segment 3 Execution Time [21] Time required for last Segment 3.
IPS20 Actual End of Segment 3 Position [12] Ram (Screw) position at completion of last Segment 3.
IPS21 Actual Segment 4 Velocity [05] or [06] Average ram (screw) velocity during last Segment 4.
If IPC03-B14 is RESET, the module reports this average in percent velocity.
If IPC03-B14 is SET, it reports it in in.(mm)/s.
IPS22 Actual Segment 4 Pressure [01] Average ram (screw) pressure during last Segment 4.