2–99Command Word/Bit Descriptions
Publication
1771-6.5.88 – July 1997
SCC
Output Ramp Rate
The module uses the following ramp rates when moving its outputs
from setpoint to setpoint during the Second Clamp Close Profile.
The module interprets a ramp rate entry of zero as a step function
ramp (ramp disable).
Word Description
SCC17 Output #1 Acceleration Ramp Rate during Profile [20]
SCC18 Output #2 Acceleration Ramp Rate during Profile [20]
SCC19 Output #3 Acceleration Ramp Rate during Profile [20]
SCC20 Output #4 Acceleration Ramp Rate during Profile [20]
SCC21 Output #5 Acceleration Ramp Rate during Profile [20]
SCC22 Output #6 Acceleration Ramp Rate during Profile [20]
SCC23 Output #7 Acceleration Ramp Rate during Profile [20]
SCC24 Output #8 Acceleration Ramp Rate during Profile [20]
SCC25 Output #1 Deceleration Ramp Rate during Profile [20]
SCC26 Output #2 Deceleration Ramp Rate during Profile [20]
SCC27 Output #3 Deceleration Ramp Rate during Profile [20]
SCC28 Output #4 Deceleration Ramp Rate during Profile [20]
SCC29 Output #5 Deceleration Ramp Rate during Profile [20]
SCC30 Output #6 Deceleration Ramp Rate during Profile [20]
SCC31 Output #7 Deceleration Ramp Rate during Profile [20]
SCC32 Output #8 Deceleration Ramp Rate during Profile [20]
End of Profile Set-output Values
When the module completes the second clamp close profile and
CPC03-B09 is set, it:
sets its outputs to the following values
sets status bit SYS22-B01
uses ramp rates SCC17 - 32 when changing outputs to these values
Use these values for setting cores if applied before starting the Third
Clamp Close Profile:
Word Description
SCC33 Output #1 Set-output Value at End of Profile [19]
SCC34 Output #2 Set-output Value at End of Profile [19]
SCC35 Output #3 Set-output Value at End of Profile [19]
SCC36 Output #4 Set-output Value at End of Profile [19]
SCC37 Output #5 Set-output Value at End of Profile [19]
SCC38 Output #6 Set-output Value at End of Profile [19]
SCC39 Output #7 Set-output Value at End of Profile [19]
SCC40 Output #8 Set-output Value at End of Profile [19]