Notes: 1. For [ ] engineering units, see page 3.
2. When using the Inject/Clamp/Eject mode, all pressure readings are system pressure at input 2, except where noted.
Output Ramp Rates
The module uses the following ramp rates when moving its outputs
from setpoint to setpoint during the First Clamp Close Profile. The
module interprets a ramp rate entry of zero as a step function ramp
(ramp disable).
Word Description
FCC17 Output #1 Acceleration Ramp Rate during Profile [20]
FCC18 Output #2 Acceleration Ramp Rate during Profile [20]
FCC19 Output #3 Acceleration Ramp Rate during Profile [20]
FCC20 Output #4 Acceleration Ramp Rate during Profile [20]
FCC21 Output #5 Acceleration Ramp Rate during Profile [20]
FCC22 Output #6 Acceleration Ramp Rate during Profile [20]
FCC23 Output #7 Acceleration Ramp Rate during Profile [20]
FCC24 Output #8 Acceleration Ramp Rate during Profile [20]
FCC25 Output #1 Deceleration Ramp Rate during Profile [20]
FCC26 Output #2 Deceleration Ramp Rate during Profile [20]
FCC27 Output #3 Deceleration Ramp Rate during Profile [20]
FCC28 Output #4 Deceleration Ramp Rate during Profile [20]
FCC29 Output #5 Deceleration Ramp Rate during Profile [20]
FCC30 Output #6 Deceleration Ramp Rate during Profile [20]
FCC31 Output #7 Deceleration Ramp Rate during Profile [20]
FCC32 Output #8 Deceleration Ramp Rate during Profile [20]
End of Profile Set-output Values
When the module completes the First Clamp Close Profile and
CPC03-B08 is SET, it:
sets its outputs to the following values
sets status bit SYS22-B00
uses ramp rates FCC17 - FCC32 when changing outputs to these
values
Use these values for setting cores if applied before starting the
Second Clamp Close Profile.
Word Description
FCC33 Output #1 Set-output Value at End of Profile [19]
FCC34 Output #2 Set-output Value at End of Profile [19]
FCC35 Output #3 Set-output Value at End of Profile [19]
FCC36 Output #4 Set-output Value at End of Profile [19]
FCC37 Output #5 Set-output Value at End of Profile [19]
FCC38 Output #6 Set-output Value at End of Profile [19]
FCC39 Output #7 Set-output Value at End of Profile [19]
FCC40 Output #8 Set-output Value at End of Profile [19]