User guide
Enter
Y
our V
alues Here
Load Initial Configuration Values
Chapter 7
7-6
Worksheet 7B
(continued)
Low Pressure Close Configuration Block (LPC)
For these Parameters (footnote = units) Word LPC N43: LPC Value
Minimum ERC Percentage
8
06 182 1000
Tonnage Watchdog Timer Preset
1
07 183 0
Profile Watchdog Timer Preset
1
08 184 0
#1 Selected Valve SetOutput During Profile
4
09 185 *
#2 Selected Valve SetOutput During Profile
4
10 186 *
#3 Selected Valve SetOutput During Profile
4
11 187 *
#4 Selected Valve SetOutput During Profile
4
12 188 *
Output #1 Acceleration Ramp Rate During Profile
5
17 193 0
Output #2 Acceleration Ramp Rate During Profile
5
18 194 0
Output #3 Acceleration Ramp Rate During Profile
5
19 195 0
Output #4 Acceleration Ramp Rate During Profile
5
20 196 0
Output #1 Deceleration Ramp Rate During Profile
5
25 201 0
Output #2 Deceleration Ramp Rate During Profile
5
26 202 0
Output #3 Deceleration Ramp Rate During Profile
5
27 203 0
Output #4 Deceleration Ramp Rate During Profile
5
28 204 0
#1 Endofprofile Setoutput Value
4
33 209 *
#2 Endofprofile Setoutput Value
4
34 210 *
#3 Endofprofile Setoutput Value
4
35 211 *
#4 Endofprofile Setoutput Value
4
36 212 *
Pressure Minimum Control Limit
3
41 217 0
Pressure Maximum Control Limit
3
42 218 System Pressure
Selected Pressure Valve Output for Minimum
4
43 219 *
Selected Pressure Valve Output for Maximum
4
44 220 *
Proportional Gain for Pressure Control
(none)
49 225 100
Integral Gain for Pressure Control
6
50 226 400
Derivative Gain for Pressure Control
7
51 227 0
Profile High Pressure Alarm Setpoint
3
57 233 0
1
Time
3
Pressure
4
Percent
Signal Output
5
Percent Signal Output per Sec
00.00 to 99.99 Sec 0000 to 9999 PSI
00.00 to 99.99
0000 to 9999
000.0 to 999.9 Bar
6
Inverse T
ime (Algorithm)
7
T
ime (Algorithm)
8
Percent
00.00 to 99.99 Minutes 00.00 to 99.99 Minutes
00.00 to 99.99
00.00 to 99.99 Sec
* Important
: Refer to the appropriate section later in this chapter for information on this parameter