User guide

Load Initial Configuration Values
Chapter 7
7-2
The following table lists configuration blocks and corresponding
worksheets for recording your initial values to configure the QDC module.
To configure the QDC module with these configuration blocks: Use worksheet: On page:
Clamp Close Configuration Blocks (FCC, SCC, and TCC) 7A 73
Low Pressure Close Configuration Block (LPC) 7B 75
Injection Configuration Block (INC) 7C 77
Pack Configuration Block (PKC) 7D 79
Hold Configuration Block (HDC) 7E 711
Plastication Configuration Block (PLC) 7F 713
Clamp Open Configuration Blocks (FOC, SOC, TOC, and OSC) 7G 715
Ejector Configuration Blocks (EAC and ERC) 7H 717
Important: We omitted pre- and post-decompression blocks because you
do not use them when spanning valves in chapter 9. We discuss their
application in chapter 10.
Take a moment now to browse through the worksheets. Notice that we
grouped clamp close configuration blocks onto one worksheet, and clamp
open configuration blocks onto another because they are similar.
Otherwise, each configuration block has its own worksheet.
Each configuration block has two types of storage words:
control words for selecting parameters by setting bits
data words for recording initial values
Many parameters repeat from one configuration block to the next. Because
of this, we describe how you determine an initial value once for all
configuration blocks that require it. Then you enter that parameter in all
applicable configuration blocks. That is why we placed worksheets
together, followed by the text to describe how to determine initial values.
We give you the procedure immediately following the worksheets.
Use
These W
orksheets