User guide
Select Command and Status Bits to
Sequence Machine Operation
Chapter 6
6-10
Table 6.G
(continued)
Command and Configuration Bits
Operation: Function Enabled
(when = 1):
QDC Block
Address:
ProSet
Address:
Logical Bridge set output @ end of 1st clamp close profile
(0 = start 2nd clamp close profile)
CPC03B08 B37/296
set output @ end of 2nd clamp close profile
(0 = start 3rd clamp close profile)
CPC03B09 B37/297
set output @ end of 3rd clamp close profile
(0 = start clamp LP close profile)
CPC03B10 B37/298
set output @ end of hold profile
(0 = start predecompress movement @ end of hold)
HPC03B08 B38/296
set output @ end of predecompress movement
(0 = start plastication profile @ end of predecompress)
HPC03B09 B38/297
set output at end of plastication profile
(0 = start postdecompression at end of plastication)
PPC03B08 B38/488
set output @ end of 1st clamp open profile
(0 = start 2nd clamp open profile)
OPC03B08 B37/616
set output @ end of 2nd clamp open profile
(0 = start 3rd clamp open profile)
OPC03B09 B37/617
set output @ end of 3rd clamp open profile
(0 = start clamp open slow profile)
OPC03B10 B37/618
set output @ end of all ejector strokes
(0 = start each new stroke at end of previous)
EPC03B12 B39/172
Configured
Protection from
Clampzone
Overrun
If a clamp close profile overruns the
mold protection zone:
0 = start LPclose profile
1 = stop and zero outputs
CPC03B11 B37/299
If a clamp open profile overruns the
clamp open slow zone
0 = start open slow profile
1 = stop and zero outputs
OPC03B11 B37/619
Additional Ejector
Configuration
start ejector profile on command from PLC processor
(0 = start ejector profile on position during clamp open)
EPC03B08 B39/168
disable ejector profile
(0 = enable ejector profile)
EPC03B09 B39/169
change intermediate strokes to tip strokes
(0 = all ejector strokes are full strokes)
EPC03B13 B39/173
execute forward dwell after 1st advance stroke
(0 = execute forward dwell after last advance stroke)
EPC03B15 B39/175