User guide

Select Command and Status Bits to
Sequence Machine Operation
Chapter 6
6-9
Table 6.G
Command
and Configuration Bits
Operation: Function Enabled
(when = 1):
QDC Block
Address:
ProSet
B34/xx:
Nonprofiled execute setoutput DYC01B08 392
Action Commands execute unassigned # 1 jog DYC01B09 393
execute ram (screw) forward jog DYC01B10 394
execute ram (screw) reverse jog DYC01B11 395
execute clamp forward jog DYC01B12 396
execute clamp reverse jog DYC01B13 397
execute ejector advance jog DYC01B14 398
execute ejector retract jog DYC01B15 399
Profile Action execute 1st clamp close profile DYC02B00 400
Commands execute 2nd clamp close profile DYC02B01 401
execute 3rd clamp close profile DYC02B02 402
execute LP clamp close profile DYC02B03 403
execute injection profile DYC02B04 404
execute pack profile DYC02B05 405
execute hold profile DYC02B06 406
execute predecompression movement DYC02B07 407
execute plastication profile DYC02B08 408
execute postdecompression movement DYC02B09 409
execute 1st clamp open profile DYC02B10 410
execute 2nd clamp open profile DYC02B11 411
execute 3rd clamp open profile DYC02B12 412
execute clamp open slow profile DYC02B13 413
execute ejector profile DYC02B14 414
Stop Command execute all stop (outputs = zero) DYC02B15 415
Miscellaneous reset tonnage watchdog timer DYC03B00 416
Commands reset cure timer DYC03B01 417
reset SYS01B08 DYC03B08 424
reset latched alarms DYC03B09 425
reset complete bits DYC03B10 426
continue ejector profile DYC03B15 431