User guide

Select Command and Status Bits to
Sequence Machine Operation
Chapter 6
6-7
Table 6.F
Status
Bits (continued)
Category: Bit Status
(when = 1):
QDC Block
Address
ProSet
B34/xx:
ejector forward dwell timer is timing SYS03B10 42
cycle complete SYS03B11 43
ejector fully advanced SYS03B12 44
ejector is beyond tip advance position SYS03B13 45
ejector is within tip retract position SYS03B14 46
ejector fully retracted SYS03B15 47
Watchdog Status 1st clamp close watchdog timed out SYS04B00 48
2nd clamp close watchdog timed out SYS04B01 49
3rd clamp close watchdog timed out SYS04B02 50
LP close watchdog timed out SYS04B03 51
predecompress watchdog timed out SYS04B07 55
plastication watchdog timed out SYS04B08 56
postdecompress watchdog timed out SYS04B09 57
1st clamp open watchdog timed out SYS04B10 58
2nd clamp open watchdog timed out SYS04B11 59
3rd clamp open watchdog timed out SYS04B12 60
clamp open slow watchdog timed out SYS04B13 61
ejector watchdog timed out SYS04B14 62
tonnage watchdog timed out SYS04B15 63
Profile Status executing 1st close profile SYS21B00 320
executing 2nd close profile SYS21B01 321
executing 3rd close profile SYS21B02 322
executing LP close profile SYS21B03 323
executing injection profile SYS21B04 324
executing pack profile SYS21B05 325
executing hold profile SYS21B06 326
executing predecompress movement SYS21B07 327
executing plastication profile SYS21B08 328
executing postdecompress movement SYS21B09 329
executing 1st clamp open profile SYS21B10 330
executing 2nd clamp open profile SYS21B11 331
executing 3rd clamp open profile SYS21B12 332