User guide
Select Command and Status Bits to
Sequence Machine Operation
Chapter 6
6-4
Table 6.D
Command
Bits T
o Interrupt Movement Between Profiles
To Perform T his Function Use This Bit ProSet
Address:
Start 2nd clamp close profile @ endof 1st
Stop and setoutput @ endof 1st
CPC03B08 = 0
= 1
B37/296
Start 3rd clamp close profile @ endof 2nd
Stop and setoutput @ endof 2nd
CPC03B09 = 0
= 1
B37/297
Start LP close profile @ endof 3rd
Stop and setoutput @ endof 3rd
CPC03B10 = 0
= 1
B37/298
Start 2nd clamp open profile @ endof 1st
Stop and setoutput @ endof 1st
OPC03B08 = 0
= 1
B37/616
Start 3rd clamp open profile @ endof 2nd
Stop and setoutput @ endof 2nd
OPC03B09 = 0
= 1
B37/617
Start clamp open slow profile @ endof 3rd
Stop and setoutput @ endof 3rd
OPC03B10 = 0
= 1
B37/618
Start ejector profile on clamp position
Start ejector profile on command
EPC03B08 = 0
= 1
B39/168
Enable ejector profile
Disable ejector profile
EPC03B09 = 0
= 1
B39/169
Run ejector profile without interruption
Stop and notify @ end of ejector stroke
EPC03B12 = 0
= 1
B39/172
Start predecompression movement @ endof hold
Stop and set output @ endof hold
HPC03B08 = 0
= 1
B38/296
Start plastication profile @ endof predecompression
Stop and set output @ endof predecompression
HPC03B09 = 0
= 1
B38/297
Start postdecompression movement @ endof plastication
Stop and set output @ endof plastication
PPC03B08 = 0
= 1
B38/488
Important: In any of these bit tables, disregard bits not needed by your
application.