User guide
Select
Input 1 (Ram Screw Position) Range with bits 01, 00
Select Input 2 (System Pressure) Range with bits 03, 02
Select Input 3 (Clamp Position) Range with bits 05, 04
Select Input 4 (Ejector Position) Range with bits 07, 06
Input Range
0 - 10V dc 0 0
1 - 5V dc 0 1
4 - 20 mA 1 0
Not connected 1 1
Select
Output 1 Range with bits 01, 00
Select Output 2 Range with bits 03, 02
Select Output 3 Range with bits 05, 04
Select Output 4 Range with bits 07, 06
Output
Range -10
to +10V dc0 0
0 to +10V dc 0 1
4 to 20 mA 1 0
Not connected 1 1
Configure the QDC Module's I/O
Chapter 3
3-3
Worksheet 3B
Select
Input Ranges for your Sensors
Control W
ord MCC03Bxx
15 14 13 12
11 10
09 08 07 06 05 04 03 02 01 00
ProSet 600 Addr. B34/bit
559 558 557 556 555 554 553 552 551 550 549 548 547 546 545 544
Value 1 1 1 1 1 1 1 1
Example: If you select an input range of 4-20 mA for all four inputs:
MCC03 = 11111111 10101010.
Important: Software input selections must match the jumper settings for
each respective input.
Worksheet 3C
Select
Output Ranges for your V
alves
Control W
ord MCC04Bxx
15 14 13 12
11 10
09 08 07 06 05 04 03 02 01 00
ProSet 600 Addr. B34/bit
575 574 573 572 571 570 569 568 567 566 565 564 563 562 561 560
Value 1 1 1 1 1 1 1 1
Example: If you select 0-10V dc for all four output ranges:
MCC04 = 11111111 01010101.
Important: Software output selections must match the jumper settings for
each respective output.