Worksheet 7A
(continued)
Clamp Close Configuration Blocks (FCC, SCC, and TCC)
For these Parameters (footnote = units) Word FCC N43: FCC Value SCC N43: SCC Value TCC N43: TCC Value
Minimum ERC Percentage - Velocity
8
05 1 1000 61 1000 121 1000
Minimum ERC Percentage - Pressure
8
06 2 1000 62 1000 122 1000
Profile Watchdog Timer Preset
1
08 4 0 64 0 124 0
Output #1 Selected Valve %Output During Profile
4
09 5 * 65 * 125 *
Output #2 Selected Valve %Output During Profile
4
10 6 * 66 * 126 *
Output #3 Selected Valve %Output During Profile
4
11 7 * 67 * 127 *
Output #4 Selected Valve %Output During Profile
4
12 8 * 68 * 128 *
Output #1 Acceleration Ramp Rate During Profile
5
17 13 0 73 0 133 0
Output #2 Acceleration Ramp Rate During Profile
5
18 14 0 74 0 134 0
Output #3 Acceleration Ramp Rate During Profile
5
19 15 0 75 0 135 0
Output #4 Acceleration Ramp Rate During Profile
5
20 16 0 76 0 136 0
Output #1 Deceleration Ramp Rate During Profile
5
25 21 0 81 0 141 0
Output #2 Deceleration Ramp Rate During Profile
5
26 22 0 82 0 142 0
Output #3 Deceleration Ramp Rate During Profile
5
27 23 0 83 0 143 0
Output #4 Deceleration Ramp Rate During Profile
5
28 24 0 84 0 144 0
Output #1 Endofprofile Setoutput Value
4
33 29 * 89 * 149 *
Output #2 Endofprofile Setoutput Value
4
34 30 * 90 * 150 *
Output #3 Endofprofile Setoutput Value
4
35 31 * 91 * 151 *
Output #4 Endofprofile Setoutput Value
4
36 32 * 92 * 152 *
Pressure Minimum Control Limit
3
41 37 0 97 0 157 0
Pressure Maximum Control Limit
3
42 38 Syst Press 98 Syst Press 158 Syst Press
Selected Pressure Valve Output for Minimum
4
43 39 * 99 * 159 *
Selected Pressure Valve Output for Maximum
4
44 40 * 100 * 160 *
Velocity Minimum Control Limit
2
45 41 0 101 0 161 0
Velocity Maximum Control Limit
2
46 42 per OEM * 102 per OEM * 162 per OEM *
Selected Velocity Valve Output for Minimum
4
47 43 * 103 * 163 *
Selected Velocity Valve Output for Maximum
4
48 44 * 104 * 164 *
Proportional Gain for Pressure Control
(none)
49 45 100 105 100 165 100
Integral Gain for Pressure Control
6
50 46 400 106 400 166 400
Derivative Gain for Pressure Control
7
51 47 0 107 0 167 0
Proportional Gain for Velocity Control
6
52 48 200 108 200 168 200
Feed Forward Gain for Velocity Control
(none)
53 49 0 109 0 169 0
Profile High Pressure Alarm Setpoint
3
57 53 0 113 0 173 0
1
Time
2
Velocity along Axis
3
Pressure
4
Percent Signal Output
00.00 to 99.99 Seconds 00.00 to 99.99 Inches per Second 0000 to 9999 PSI
00.00 to 99.99
000.0 to 999.9 Millimeters per Sec
000.0 to 999.9 Bar
5
Percent Signal Output per Second
6
Inverse T
ime (Algorithm)
7
T
ime (Algorithm)
8
Percent
0000 to 9999
00.00 to 99.99 Minutes 00.00 to 99.99 Minutes
00.00 to 99.99
00.00 to 99.99 Seconds
*Important