User guide

Span Your Valves
Chapter 9
9-32
On
Worksheet
Confirm Your Configuration With These Words or Bits
for Hold Pressure
ProSet Addr
8C Pressure vs Time algorithm
for Pack and Hold
HPC03B02 = B00 = 0 B38/288, 290
Logical bridge to stop and set outputs before:
predecompression
plastication
HPC03B08 = 1
HPC03B09 = 1
B38/296
B38/297
Openloop control HPC04B03, B02, B01, B00 = 1 B38/304307
Expert Response Compensation (ERC) = Off HPC04B11, B10, B09, B08 = 1 B38/312315
Pressure setpoints HPC10,13,16,19,22,27,30,33,36,
39 all equal full injection pressure
start @ N44:246
end @ N44:275
Time setpoints HPC11,14,17,20,23,28,31,34,37
40 all equal to 1 second (100)
start @ N44:247
end @ N44:276
If these are not your current values, we suggest that you correct them now
and download them using the download procedure discussed in chapter 4.
Before proceeding, observe these warnings:
ATTENTION: As with any machine start-up, install a test
mold. Programming errors, configuration errors, or hydraulic
problems could lead to personal injury and/or machine damage.
ATTENTION: Be sure all machine guards and shields are in
place before proceeding to guard against personal injury.